Table 3 Extended Langmuir and extended Sips parameters for BB and CR adsorption onto B-8 N in binary systems.
Models | BB | RC | |||||
|---|---|---|---|---|---|---|---|
Parameters | 25 °C | 55 °C | Parameters | 25 °C | 55 °C | ||
Extended Langmuir | Qmax1 (mg g− 1) | 139.330 | 386 | Qmax2 (mg g− 1) | 333.199 | 249.228 | |
K1 | 0.018 | 0.008 | K1 | 3.273E-23 | 2.72 E-17 | ||
K2 | 0.012 | 0.007 | K2 | 0.007 | 0.447 | ||
R² | 0.949 | 0.992 | R² | 0.973 | 0.937 | ||
ꭓ² | 125.569 | 27.018 | ꭓ² | 317.762 | 692.751 | ||
Extended Sips | Qmax1 (mg g− 1) | 106.406 | 170.00 | Qmax2 (mg g− 1) | 253.386 | 253.091 | |
K1 (L mg− 1) | 2.098E-7 | 8.53E-16 | K1 (L mg− 1) | 0.317 | 0.423 | ||
K2 (L mg− 1) | 0.030 | 0.653 | K2 (L mg− 1) | 7.079E-16 | 1.58E-12 | ||
ms | 2.301 | 0.557 | ms | 0.771 | 0.950 | ||
R² | 0.983 | 0.950 | R² | 0.942 | 0.937 | ||
ꭓ² | 51.146 | 210.712 | ꭓ² | 849.417 | 830.205 | ||