Table 3 Anti-disturbance experimental data.
From: Synchronous reluctance motor speed control based on multivariable Super-Twisting
Control method | Maximum drop (r/min) | Adjustment time (s) | Maximum overshoot (r/min) | Adjustment time (s) |
|---|---|---|---|---|
Scheme 1 | 43 | 0.64 | 31 | 0.68 |
Scheme 2 | 102 | 0.78 | 92 | 0.85 |
Scheme 3 | 248 | 1.23 | 279 | 1.37 |