Table 5 Original vs. optimized curing set points for five underperforming batches.

From: Monitoring of ultra-high performance concrete manufacturing for reproducible quality and waste reduction

Exp. Nr.

IM

SAI

FLI

SPP

IT

GRP

APW

Original

Optimized

CT1

CC1

CT28

CC28

CS28

CT1

CC1

CT28

CC28

CS28

47

3.364

6

6.9

0.339

40

0.045

1.07

40

2

10

2

85.70

33

1

31

1

117.56

53

3.276

6.9

5.7

0.323

20

0.225

1.04

40

2

40

2

105.11

34

1

36

2

121.74

99

3.042

6

5.1

0.323

25

0.225

1.21

10

2

20

1

107.87

26

2

33

2

119.58

123

2.925

6

6

0.323

25

0

1.18

20

1

10

2

95.94

15

2

25

1

118.26

139

3.364

5.4

5.7

0.29

25

0

1.18

20

1

20

1

107.86

10

1

27

2

120.68

  1. The table lists the original curing conditions alongside the model-recommended optimized values for early-age curing (CT1, CC1) and long-term curing (CT28, CC28), as well as the corresponding 28-day compressive strengths achieved. Abbreviations are defined in Table 1. (Exp. Nr.: Experiment number (after removing the outliers)).