Table 5 Comparison of RMS current and conduction-loss.

From: Fuzzy logic-based reactive power control for power factor enhancement in EV drives

Metric

FOC (baseline)

FRC (proposed)

Relative change

Power (active) \(\:P\)

750 W (same in both cases)

750 W

Power factor (measured)

0.74

0.79

Line RMS current \(\:{I}_{\text{rms}}\)(measured/calculated)

1.410 A

1.321 A

−6.33%

Estimated conduction loss \(\:{I}^{2}R\)(relative)

1.000 (reference)

0.877

−12.26%