Table 1 Parameters of the scale model.

From: Sensing the restoring force characteristics for detached house structural health monitoring using a camera and accelerometer fusion

M (kg)

W (mm)

D (mm)

H (mm)

Young’s modulus: E (GPa)

Moment of inertia of area: I (m4)

2

300

250

500

70

1.66667 × 10− 10

a (mm)

b (mm)

c (mm)

Rigidity of the plate: k (N/m)

Natural frequency: f (Hz)

Amount of deformation: Δ (mm)

2

10

15

2240

5.33

8.75