Table 3 The proposed fuzzy logic controller is based on rules.
From: A new approach for improving dynamic fault ride through capability of gridctied based wind turbines
Rule # | \(\:{V}_{m}\) | \(\:{F}_{m}\) | \(\:{I}_{r}\) | Rule # | \(\:{V}_{m}\) | \(\:{F}_{m}\) | \(\:{I}_{r}\) |
|---|---|---|---|---|---|---|---|
01 | PS | PS | PS | 09 | PS | PM | NM |
02 | ZO | PS | ZO | 10 | ZO | PM | NS |
03 | PM | PS | PM | 11 | PM | PM | PS |
04 | PB | PS | PB | 12 | PB | PM | ZO |
05 | PS | ZO | NS | 13 | PS | PB | NB |
06 | ZO | ZO | PS | 14 | ZO | PB | NM |
07 | PM | ZO | ZO | 15 | PM | PB | NS |
08 | PB | ZO | PM | 16 | PB | PB | PS |