Table 1 General specifications and thermal and electrical characteristics of the PVT solar collector.
Element | Information |
|---|---|
General specifications | |
Empty weight | 46.6 kg |
Cell numbers | 60 |
Absorption plate | Copper |
Thermal conductivity of the plate | 385 W m−1 K−1 |
Plate dimensions | 1645 × 978 × 104 mm |
Capture surface | 1.55 m2 |
External coil diameter | 22 mm |
Cover | Glass |
Cover thickness | 4 mm |
Insulation | Rock wool |
Insulation thickness | 60 mm |
Thermal specifications | |
Maximum pressure | 6 bar |
Capacity | 1.27 L |
Optical performance | 0.507 |
Coefficient of thermal losses (a1) | 4.934 W m−2 K−1 |
Coefficient of thermal losses (a2) | 0.021 W m−2 K−1 |
Stagnation temperature | 148.9 °C |
Electrics specifications | |
Power | 255 W |
Open-circuit voltage (Vac) | 37.9 V |
Nominal voltage (Vmpp) | 31.25 V |
Short-circuit current (Iac) | 9.30 A |
Nominal current (Impp) | 8.70 A |
Maximum reverse current | 15.0 A |
Maximum system voltage | 1000 V |