Table 5 Study of the effect of changing the amplitude of the fundamental signal (50 Hz) and the THD current between the second and first experiments.
From: Experimental verification of the six sectors neural DTC approach of squirrel cage induction motors
DTC approach | DTC-NN approach | ||
|---|---|---|---|
Amplitude of fundamental signal (50 Hz) | Test 1 | 3.29 | 3.21 |
Test 2 | 3.29 | 3.22 | |
Test 2 – Test 1 | 00 | + 0.01 | |
Ratios (%) | 00 | 0.31 | |
THD (%) | Test 1 | 12.83 | 10.23 |
Test 2 | 19.09 | 13.93 | |
Test 2 – Test 1 | + 6.26 | + 3.7 | |
Ratios (%) | 32.79 | 26.56 | |