Table 3 Physical specifications of the liquid-liquid systems (20 °C).

From: Machine learning and response surface analysis of mean drop size and dispersed phase holdup in an L-shaped pulsed sieve plate column

Physical properties

Two-phase liquid system

Kerosene-Water

5% (v/v) TBP/Kerosene- 17% Nitric Acid

15% (v/v) TBP/Kerosene- 17% Nitric Acid

30% (v/v) TBP/Kerosene-17% Nitric Acid

σ (mN/m)

36.00

21.00

15.10

9.95

µc (mPa.s)

1.00

1.76

1.76

1.76

µd (mPa.s)

1.66

1.71

1.87

2.25

ρc (kg/m3)

998.00

1088.00

1088.00

1088.00

ρd (kg/m3)

790.00

801.10

822.70

853.20