Table 3 Dynamic performance for DC-link voltage regulation using FLC, ANFIS, FOPI, FOFL and FLSMC during swell.

From: Fuzzy logic sliding mode controller based solar PV fed UPQC for improvement of dynamic performance and power quality enhancement in distribution power system

S.no

Controller

Overshoot (%)

\(T_{s}\) (ms)

Tr (ms)

1

With PI

11.5

1.98

1.6

2

With FLC

10

1.9

1.4

3

With ANFIS

8.50

1.4

1.2

4

With FOFLC

6.40

1.2

0.8

5

With FLSMC

5.42

1.01

0.6