Table 4 Dynamic performance for DC-link voltage regulation using FLC, ANFIS, FOP and FOFL and FLSMC during sag.
S.no | Controller | Overshoot (%) | \(T_{s}\) (ms) | Tr (ms) |
|---|---|---|---|---|
1 | With PI | 9.6 | 1.99 | 1.9 |
2 | With FLC | 8 | 1.95 | 1.8 |
3 | With ANFIS | 5.50 | 1.9 | 1.75 |
4 | With FOFLC | 4.30 | 1.8 | 1.65 |
5 | With FLSMC | 3.90 | 1.75 | 1.32 |