Table 4 Electrical conductivity measurements of biocomposite films considering sample geometry at room temperature.

From: Polyhydroxybutyrate / carbonized waste rubber biocomposite films

Sample

R calculated

(Ω)

Length (mm)

Thickness

(mm)

Width (mm)

Electrical conductivity (S/m)

F0

70 × 106

60

0,33

10

2.60 × 10− 4

F1

45 × 106

60

0,30

10

4.44 × 10− 4

F2

30 × 106

60

0,32

10

6.25 × 10− 4

F3

40 × 106

60

0,32

10

4.69 × 10− 4