Abstract
The fluctuation of circuit pressure parameters may reflect the severity of circuit clotting, but it is unclear yet which one has the highest precision for the prediction of filter clotting. Increased filter pressure drop (FPD) and transmembrane pressure (TMP) are associated with filter coagulation during continuous renal replacement therapy (CRRT). They are affected by blood flow velocity and ultrafiltration rate, which can lead to false coagulation alarms. To eliminate these effects, we proposed two parameters: blood flow resistance (BFR) and transmembrane flow Resistance (TFR), and explored their role in predicting filter clotting. We conducted a retrospective analysis of patients who underwent CRRT at Jinling Hospital between March and June 2025, and experienced at least one filter change due to clotting during CRRT. CRRT modes included continuous veno-venous hemofiltration (CVVH) and hemodialysis (CVVHD). The records of continuously monitored circuit pressure parameters were extracted. The calculated parameters, including filter pressure drop (FPD), blood flow rate-adjusted FPD(blood flow resistance, BFR), transmembrane pressure (TMP), and ultrafiltration rate-adjusted TMP(transmembrane flow resistance, TFR), were further analyzed for the association of their changes with filter clotting. To verify the necessity of adjusting FPD by blood flow rate and TMP by ultrafiltration rate, a prospective study was conducted to investigate the effect of variations in blood flow rate and ultrafiltration rate on 4 pressure parameters by intentionally stepwise modulating flow rate during the start period of the CRRT session. A total of 96 CRRT circuits (76 CVVHD and 20 CVVH) from 51 patients were included. In CVVHD mode, the efficacy of ΔBFR and ΔFPD was significantly higher than that of ΔTFR and ΔTMP (all p < 0.001) for the prediction of 1-hour later clotting. AUC of ΔBFR was bigger than that of ΔFPD, although non-significant. In CVVH mode, the AUC of ΔTFR and ΔTMP was bigger than that of ΔBFR and ΔFPD, although non-significantly (all p > 0.05). A Combination of ΔBFR and ΔTFR by the parallel rule (positive if ΔBFR > 0.075 mmHg/(ml/min) or ΔTFR > 0.115 mmHg/(ml/h)) had yielded a sensitivity of 77.1% and a specificity of 62.9% for the prediction of 1-hour later filter clotting irrespective of CRRT mode. The prospective part of the study showed that FPD was blood flow rate-dependent but not BFR, and TMP was ultrafiltration rate-dependent but not TFR. BFR (Blood flow rate-adjusted FPD) and TFR (ultrafiltration rate-adjusted TMP) are potential predictors of filter clotting, warranting further studies to verify their value.
Similar content being viewed by others
Data availability
The data that support the findings of this study are available from the corresponding author upon reasonable request.
References
Karkar, A. & Ronco, C. Prescription of CRRT: A pathway to optimize therapy. Ann. Intensive Care 10, 32. https://doi.org/10.1186/s13613-020-0648-y (2020).
Uchino, S., Fealy, N., Baldwin, I., Morimatsu, H. & Bellomo, R. Continuous is not continuous: The incidence and impact of circuit “down-time” on uraemic control during continuous veno-venous haemofiltration. Intensive Care Med. 29, 575–578. https://doi.org/10.1007/s00134-003-1672-8 (2003).
Boyle, M. & Baldwin, I. Understanding the continuous renal replacement therapy circuit for acute renal failure support: A quality issue in the intensive care unit. AACN Adv. Crit. Care 21, 367–375. https://doi.org/10.1097/NCI.0b013e3181f95673 (2010).
Joannidis, M. & Oudemans-van Straaten, H. M. Clinical review: Patency of the circuit in continuous renal replacement therapy. Crit Care 11, 218. https://doi.org/10.1186/cc5937 (2007).
De Troyer, M. et al. Risk for excessive anticoagulation during hemodialysis is associated with type of vascular access and bedside coagulation testing: Results of a cross-sectional study. Front Med-Lausanne 9 (2022). https://doi.org/10.3389/fmed.2022.1009748.
Hang, C. et al. Optimal indicator for changing the filter during the continuous renal replacement therapy in intensive care unit patients with acute kidney injury: A crossover randomized trial. World J. Emerg. Med. 13, 196–201. https://doi.org/10.5847/wjem.j.1920-8642.2022.046 (2022).
Kakajiwala, A. et al. Membrane pressures predict clotting of pediatric continuous renal replacement therapy circuits. Pediatr. Nephrol. 32, 1251–1261. https://doi.org/10.1007/s00467-017-3601-z (2017).
Holt, A. W., Bierer, P., Bersten, A. D., Bury, L. K. & Vedig, A. E. Continuous renal replacement therapy in critically ill patients: Monitoring circuit function. Anaesth. Intensive Care 24, 423–429. https://doi.org/10.1177/0310057X9602400402 (1996).
Ficheux, A., Kerr, P. G., Brunet, P. & Argiles, A. The ultrafiltration coefficient of a dialyser (KUF) is not a fixed value, and it follows a parabolic function: The new concept of KUF max. Nephrol. Dial. Transplant. 26, 636–640. https://doi.org/10.1093/ndt/gfq510 (2011).
Yu, J., Chitalia, V. C., Akintewe, O. O., Edwards, A. & Wong, J. Y. Determinants of hemodialysis performance: Modeling fluid and solute transport in hollow-fiber dialyzers. Regen. Eng. Transl. Med. 7, 291–300. https://doi.org/10.1007/s40883-019-00135-0 (2021).
Vanommeslaeghe, F. et al. Micro-computed tomography for the quantification of blocked fibers in hemodialyzers. Sci. Rep. 8, 2677. https://doi.org/10.1038/s41598-018-20898-w (2018).
Zhou, Z. et al. Anticoagulation options for continuous renal replacement therapy in critically ill patients: A systematic review and network meta-analysis of randomized controlled trials. Crit. Care 27, 222. https://doi.org/10.1186/s13054-023-04519-1 (2023).
Brain, M., Winson, E., Roodenburg, O. & McNeil, J. Non anti-coagulant factors associated with filter life in continuous renal replacement therapy (CRRT): A systematic review and meta-analysis. BMC Nephrol. 18, 69. https://doi.org/10.1186/s12882-017-0445-5 (2017).
Mateos-Dávila, A., Roig, A. J. B., Rodríguez, J. A. S. & Guix-Comellas, E. M. Change in prefilter pressure as a key determinant in the decision to return blood in continuous renal replacement therapy: An observational study. Nurs. Crit. Care 29, 1441–1449. https://doi.org/10.1111/nicc.12933 (2024).
Ejaz, A. A., Komorski, R. M., Ellis, G. H. & Munjal, S. Extracorporeal circuit pressure profiles during continuous venovenous haemofiltration. Nurs. Crit. Care 12, 81–85. https://doi.org/10.1111/j.1478-5153.2006.00192.x (2007).
Li, P. et al. Effect of dynamic circuit pressures monitoring on the lifespan of extracorporeal circuit and the efficiency of solute removal during continuous renal replacement therapy. Front. Med. (Lausanne) 8, 621921. https://doi.org/10.3389/fmed.2021.621921 (2021).
Holt, A. W., Bierer, P., Glover, P., Plummer, J. L. & Bersten, A. D. Conventional coagulation and thromboelastograph parameters and longevity of continuous renal replacement circuits. Intensive Care Med. 28, 1649–1655. https://doi.org/10.1007/s00134-002-1506-0 (2002).
Guo, L., Hu, Y., Zeng, Q. & Yang, X. Factors affecting continuous renal replacement therapy duration in critically ill patients: A retrospective study. Ther. Apher. Dial. 27, 898–908. https://doi.org/10.1111/1744-9987.14024 (2023).
Author information
Authors and Affiliations
Contributions
Data were collected and curated by H.Y. and H.Z. Formal analysis was carried out by L.C., Y.X. Supervision of the study was done by G.Y. and G.D. The original draft was written by H.Y. Review and editing of the paper were done by all co-authors.
Corresponding authors
Ethics declarations
Competing interests
The authors declare no competing interests.
Ethics approval
This study was conducted in compliance with the Declaration of Helsinki and received approval from the Ethical Review Board of the Jinling Hospital (approval number 2025DZKY-074-02). Informed consent was obtained from each participant or an authorized family member.
Additional information
Publisher’s note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Supplementary Information
Below is the link to the electronic supplementary material.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License, which permits any non-commercial use, sharing, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if you modified the licensed material. You do not have permission under this licence to share adapted material derived from this article or parts of it. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by-nc-nd/4.0/.
About this article
Cite this article
Hu, Y., Hu, Z., Li, C. et al. Prediction of filter clotting using longitudinal trends of circuit pressure parameters during continuous renal replacement therapy (CRRT): an exploratory study. Sci Rep (2026). https://doi.org/10.1038/s41598-026-48433-2
Received:
Accepted:
Published:
DOI: https://doi.org/10.1038/s41598-026-48433-2