Table 2 Calibration data from the IBM Quantum device during the \(\sqrt{i\text {SWAP}}\) QPT experiments, providing context for the error sources contributing to the observed experimental fidelity.
From: Benchmarking engineered exchange interactions on NISQ hardware
Qubit | T\(_1\) (\(\mu\)s) | T\(_2\) (\(\mu\)s) | \(\Omega /2\pi\) (GHz) | \(\Lambda\) (GHz) | \(\delta _r\) | P(0|1) | P(1|0) | \(\varepsilon _r\) (ns) |
|---|---|---|---|---|---|---|---|---|
0 | 87.651 | 89.958 | 5.15756 | -0.34152 | 0.0281 | 0.0292 | 0.0270 | 721.78 |
1 | 193.942 | 54.158 | 5.03355 | -0.34437 | 0.0304 | 0.0320 | 0.0288 | 721.78 |
2 | 96.764 | 95.996 | 4.86266 | -0.34727 | 0.0338 | 0.0272 | 0.0404 | 721.78 |
3 | 201.576 | 227.967 | 5.12510 | -0.34044 | 0.0161 | 0.0186 | 0.0136 | 721.78 |
4 | 154.494 | 132.514 | 5.15921 | -0.33337 | 0.0293 | 0.0286 | 0.0300 | 721.78 |
5 | 128.461 | 142.089 | 4.97861 | -0.34602 | 0.0300 | 0.0344 | 0.0256 | 721.78 |
6 | 222.168 | 231.382 | 5.15664 | -0.34045 | 0.0114 | 0.0126 | 0.0102 | 721.78 |