Table 2 Performance of SEER, the PCE Score, and a composite of the two in the Stanford and Cedars-Sinai comparison sets.
From: A deep learning-based electrocardiogram risk score for long term cardiovascular death and disease
| Â | Â | Cardiovascular Mortality | Â | ASCVD events | Â |
|---|---|---|---|---|---|
| Â | Â | 5-year AUC | Harrell C-statistic | 5-year AUC | Harrell C-statistic |
Stanford | SEER | 0.795 (0.762–0.831) | 0.782 (0.759–0.817) | 0.668 (0.647–0.687) | 0.661 (0.652–0.669) |
|  | PCE | 0.651 (0.593–0.707) | 0.658 (0.614–0.672) | 0.708 (0.689–0.726) | 0.703 (0.688–0.714) |
|  | Composite | 0.804 (0.771–0.842) | 0.795 (0.781–0.817) | 0.704 (0.685–0.722) | 0.697 (0.687–0.714) |
Cedars-Sinai | SEER | 0.779 (0.724–0.835) | 0.776 (0.724–0.802) | 0.632 (0.591–0.674) | 0.635 (0.619–0.652) |
|  | PCE | 0.787 (0.727–0.859) | 0.759 (0.706–0.799) | 0.658 (0.615–0.700) | 0.642 (0.612–0.668) |
|  | Composite | 0.823 (0.769–0.882) | 0.811 (0.794–0.861) | 0.672 (0.632–0.715) | 0.666 (0.643–0.692) |