Table 2 Model performance in the external tests.

From: DeepQuality improves infant retinopathy screening

 

Model

Sensitivity (95% CI)

Specificity (95% CI)

Accuracy (95% CI)

AUC (95% CI)

Location

0.885 (0.879, 0.891)

0.972 (0.969, 0.975)

0.954 (0.950, 0.958)

0.933 (0.929, 0.938)

Posterior

Illumination, macula

0.823 (0.808, 0.838)

0.926 (0.916, 0.936)

0.902 (0.890, 0.914)

0.974 (0.968, 0.980)

Illumination, optic disc

0.866 (0.853, 0.879)

0.953 (0.945, 0.961)

0.943 (0.934, 0.952)

0.984 (0.979, 0.989)

Illumination, remaining retina

0.853 (0.839, 0.867)

0.984 (0.979, 0.989)

0.977 (0.971, 0.983)

0.995 (0.992, 0.998)

Clarity, macula

0.881 (0.868, 0.894)

0.914 (0.903, 0.925)

0.905 (0.894, 0.916)

0.981 (0.976, 0.986)

Clarity, optic disc

0.835 (0.821, 0.850)

0.834 (0.820, 0.849)

0.908 (0.897, 0.919)

0.984 (0.979, 0.989)

Clarity, remaining retina

0.821 (0.806, 0.836)

0.845 (0.831, 0.859)

0.837 (0.823, 0.851)

0.952 (0.943, 0.960)

Peripheral

Integrity

0.878 (0.872, 0.885)

0.918 (0.913, 0.924)

0.908 (0.902, 0.914)

0.978 (0.975, 0.981)

Illumination

0.921 (0.916, 0.926)

0.945 (0.940, 0.950)

0.942 (0.937, 0.947)

0.989 (0.987, 0.991)

Clarity

0.879 (0.873, 0.886)

0.869 (0.862, 0.876)

0.874 (0.867, 0.881)

0.975 (0.972, 0.978)

  1. CI confidence interval, Location posterior or peripheral, AUC area under the receiver operating characteristic curve.