Table 1 Data collection and processing statistics for AcrB in a cycloalkane-modified amphiphilic polymer.

From: Cycloalkane-modified amphiphilic polymers provide direct extraction of membrane proteins for CryoEM analysis

 

AcrB (EMDB-12043) (PDB 7B5P)

Data collection and processing

Magnification

130,000

Voltage (kV)

300

Electron exposure (e–/Å2)

58

Defocus range (μm)

1.7–3.5

Pixel size (Å)

1.07

Symmetry imposed

C1

Initial particle images (no.)

40,2672

Final particle images (no.)

10,0932

Map resolution (Å)

3.2

 FSC threshold

0.143

Map resolution range (Å)

3.19–6.12

Refinement

Initial model used (PDB code)

6baj

Model resolution (Å)

3.3

 FSC threshold

0.5

Model resolution range (Å)

Map sharpening B factor (Å2)

−75

Model composition

 Non-hydrogen atoms

22527

 Protein residues

3153

 Ligands

0

B factors (Å2)

 Protein

46

 Ligand

 

R.m.s. deviations

 Bond lengths (Å)

0.009

 Bond angles (°)

0.997

Validation

 MolProbity score

2.71

 Clashscore

25

 Poor rotamers (%)

2.27

Ramachandran plot

 Favoured (%)

90

 Allowed (%)

9

 Disallowed (%)

1

  1. CryoEM data collection, refinement and validation statistics