Fig. 5: Evaluation of spoken-digit classification accuracy.
From: Time multiplexed single node reservoir computing enabled by transient photon magnon coupling

a Test accuracy as a function of the number of test classes. Accuracy reaches 89% at 100 test samples. b Test accuracy versus iteration count. Accuracy peaks at 89% after 80 iterations before declining due to overfitting. c Confusion matrix illustrates classification performance across all digits.