Table 1 K-Means Performance Metrics (Higher is Better)
From: AI-QuIC machine learning for automated detection of misfolded proteins in seed amplification assays
Train Type | Sensitivity | Specificity | Precision | F1-Score | Negative Support | Positive Support |
|---|---|---|---|---|---|---|
Raw | 0.89 | 0.99 | 0.38 | 0.53 | 1444 | 160 |
Metrics | 1.00 | 0.97 | 0.78 | 0.87 | 1444 | 160 |