Figure 2: Effect of the pore sizes of the NY mesh filters on permeation, recovery, and residual rate of SVF solution in membrane filtration method.

SVF solution was permeated through NY mesh filters with different pore sizes (NY-11, NY-20, NY-41, NY-60, and NY-80 mesh filters). (i) The permeation rate of the cells where SVF solution was permeated through NY mesh filters. (ii) The recovery rate of the cells where SVF solution was permeated and subsequently the culture medium was permeated through NY mesh filters. (iii) The residual rates of the cells, which were calculated from eq. (3).