Abstract
Plasmonic materials can generate strong electromagnetic fields to boost the Raman scattering of surrounding molecules, known as surface-enhanced Raman scattering. However, these electromagnetic fields are heterogeneous, with only molecules located at the ‘hotspots’, which account for ≈ 1% of the surface area, experiencing efficient enhancement. Herein, we propose patterned plasmonic trimers, consisting of a pair of plasmonic dimers at the bilateral sides and a trap particle positioned in between, to address this challenge. The trimer configuration selectively directs probe molecules to the central traps where ‘hotspots’ are located through chemical affinity, ensuring a precise spatial overlap between the probes and the location of maximum field enhancement. We investigate the Raman enhancement of the Au@Al2O3-Au-Au@Al2O3 trimers, achieving a detection limit of 10−14 M of 4-methylbenzenethiol, 4-mercaptopyridine, and 4-aminothiophenol. Moreover, single-molecule SERS sensitivity is demonstrated by a bi-analyte method. Benefiting from this sensitivity, our approach is employed for the early detection of lung tumors using fresh tissues. Our findings suggest that this approach is sensitive to adenocarcinoma but not to squamous carcinoma or benign cases, offering insights into the differentiation between lung tumor subtypes.
Similar content being viewed by others
Introduction
Surface-enhanced Raman scattering (SERS) employs plasmonic nanomaterials to generate localized intense electromagnetic fields, namely ‘hotspots’, around the materials to amplify the Raman scattering of nearby molecules, and has found widespread applications in sensing1,2,3,4, analytical chemistry5,6, catalysis7,8,9 and other fields10,11,12. The ‘hotspots’ significantly enhance the excitation efficiency of the molecules and increase their radiation transition rate, resulting in an electromagnetic enhancement up to 1010 folds13, and enabling highly sensitive molecular detection down to the single-molecule level14,15,16.
However, these ‘hotspots’, which account for only less than 1% of the surface area13,17, are highly heterogeneous, leading to the results that only the molecules that are located at the ‘hotspots’ position contribute to the majority of observed SERS signal. This heterogeneity inherently restricts the sensitivity of SERS in practical sensing applications because the amount of detectable molecules among the total is actually very small2,18. To overcome this limitation, it is essential to ensure that the target molecules and ‘hotspots’ are overlapped at the same position. However, this is challenging because the construction of ‘hotspots’ typically employs bottom-up self-assembly methods19,20,21,22, which often involve the use of surfactants that may lead to extra interference to the SERS signal, and can block the access of target molecules to the ‘hotspots’.
The solutions to address this limitation can be broadly classified into two categories. The first category includes strategies that employ techniques such as tip-enhanced Raman scattering (TERS)23,24,25,26,27, nanocavity-enhanced Raman scattering28,29,30,31, and shell-isolated nanoparticle enhanced Raman scattering (SHINERS)7,32,33 to create ‘hotspots’ at the location of the target molecules. These approaches feature a spatial resolution down to the single-molecule level, offering a proper platform to explore the fundamental physics behind SERS. However, these approaches are generally not practical for molecular sensing applications, particularly in quantitative analysis. The second category of solutions involves introducing molecules to the ‘hotspots’ using chemical linkers34,35, molecular cages36,37 or DNA molecules38,39,40,41. The linkers can filter classes of small molecules into the active ‘hotspots’ with controlled gap distance. These techniques have facilitated the detection of specific biochemical molecules like neurotransmitters42, but the limited types of chemical bonds in the linkers also limit the selection of guest Raman probes.
Here, we propose plasmonic Au@Al2O3-Au-Au@Al2O3 trimers, which are composed of a pair of dimer particles and a trap particle in between, to selective induce target molecules into the traps where ‘hotspots’ are located. The fabricated trimers were patterned over the substrate with oriented directions over square centimeter areas, enabling Raman analysis of the sample by rapid mapping. The trimer configuration results in a substantial increase in the proportion of detectable molecules and subsequent improvement in SERS sensitivity down to the single-molecule level. The sensitivity enables in-depth investigations into pathological diagnosis of lung tumors, including the potential for tumor subtyping through SERS and exploring the correlation between the tumor node metastasis (TNM) stage and SERS outcomes.
Results
Preparations and characterizations of the trimer arrays
Figure 1a, b illustrates the working principles of the plasmonic trimers. For general plasmonic structures (Fig. 1a), the ‘hotspots’, strong SERS occurs at the gap position between two plasmonic nanoparticles, whereas the molecules are randomly adsorbed on the surface, leading to the fact that most of the molecules cannot be detected in this configuration. While for the plasmonic heterogeneous trimers (Fig. 1b), the probe molecules were mostly adsorbed on the trap particle due to the differences in chemical affinity. Therefore, the probability that a molecule can experience the amplification from the ‘hotspots’ is increased, leading to higher SERS sensitivity.
Differences in working principles between the homogeneous trimers (a) and heterogeneous trimers (b). c porous AAO nanomask transferred on a substrate. d Fabrication of the plasmonic dimers by angle-resolved shadow depositions. e optional atomic layer deposition coating after the shadow depositions. f Further modulation of the pore diameter of AAO by sputtering. g Deposition of the trap particle by final vertical e-beam deposition. h Optical photos of the fabricated samples on silicon wafer and quartz substrates. The highlighted areas in (a) and (b) represent the “hotspots” region.
Figure 1c–h outlines the preparation of trimer arrays. The porous anodic aluminum oxide (AAO) membranes with a membrane thickness of 150 ± 10 nm and pore diameter of 80 ± 2 nm were prepared and transferred onto substrates as masks for e-beam evaporations (Fig. 1c). The methodologies describing the fabrication and manipulation of the AAO membranes with desired membrane thickness and pore diameter are detailed in refs. 43,44. The dimer particles with a gap distance of ≈ 20 nm were firstly fabricated by two-step angle-resolved shadow depositions (Fig. 1d). The deposition angles were controlled by tilting the samples to the desired angle, calculated based on the pore thickness and diameter. The gap distance between the dimers can be continuously modulated by adjusting the deposition angles (Supplementary Fig. 1). This is followed by optional atomic layer deposition (ALD) of 1.5 nm thick Al2O3 to form a dielectric layer on the surface on the dimers (Fig. 1e). The diameter of the AAO pores was further adjusted by magnetron sputtering (Fig. 1f), employing the same sputtering material as that will be used in the following vertical deposition. Different to e-beam evaporation, the sputtering gasified the target atoms with no directionality, and therefore, the sputtering material was mostly deposited onto the top surface of the AAO. The sputtering offers the possibility to deposit the trap particle at the gap region between the dimers in the following vertical evaporation step (Fig. 1g), and the diameter of the trap particle can be well tuned by adjusting the sputtering parameters (Supplementary Fig. 2). Afterwards, the AAO membranes were peeled off with adhesive tape, and the plasmonic trimer arrays were exposed. The prepared sample is shown in Fig. 1h, and the dimension and shape of the sample area can be controlled by cutting the AAO membranes to a suitable size. This strategy enables large-area and mass fabrication of functional trimers with aligned orientations, small gap distances, and freedom from surface chemicals, all of which are favorable for SERS studies.
This fabrication strategy allows on-demand construction of trimer structures. The materials of both the dimer particle and trap particle can be metals or oxides, and the optional ALD process can be used to further adjust the functionality. To demonstrate the universality, we have prepared different trimers including homogeneous Au-Au-Au trimers and heterogeneous Au@Al2O3-Au-Au@Al2O3, Au-Ag-Au, and Au-TiOx-Au trimers (Supplementary Fig. 3). In particular, we employed the Au@Al2O3-Au-Au@Al2O3 trimers as a typical model to illustrate how to improve the SERS performance by inducing the target molecules to the trap particle.
Figure 2a presents the scanning electron microscopy (SEM) image of the Au@Al2O3-Au-Au@Al2O3 trimers (for large-area SEM image, see Supplementary Fig. 4), suggesting that Au is deposited at the gap region between the Au@Al2O3 dimers. This is further identified by the high-angle annular dark-field scanning transmission electron microscopy (HAADF-STEM) in Fig. 2b. The elemental mappings in Fig. 2c, d unveil that Al only exists around the dimers. The transmission electron microscopy (TEM) images in Fig. 2e, f reveal that the ellipsoidal dimer particles were coated with an Al2O3 layer with a thickness of ≈ 1.5 nm, whereas the trap particle was not.
a SEM image of the Au@Al2O3-Au-Au@Al2O3 trimers. HAADF-STEM image (b) and corresponding Au (c) and Al (d) elemental mappings of the Au@Al2O3-Au-Au@Al2O3 trimers, along with TEM images for the areas marked in red (e) and blue (f). The scale bars of the elemental mapping and TEM images are 20 nm and 2 nm, respectively. Experimental (g) and simulated (h) polarized extinction spectra (horizontal: blue; perpendicular: bronze) of the Au@Al2O3-Au-Au@Al2O3 trimer arrays, respectively. i Local EM field distributions around the Au@Al2O3-Au-Au@Al2O3 trimers under parallel and perpendicular polarized excitations at 785 nm, and color scale corresponding to the change in electric field intensity. The scale bars are 20 nm. The SEM characterizations were independently repeated for dozens of times for samples from different batches, and the results were similar. The HAADF, elemental mappings and TEM were independently repeated for three times for samples from different batches, and the results were similar. Source data are provided as a Source Data file.
The plasmonic modes of the trimer arrays were characterized by polarized UV-vis spectroscopy. The results in Fig. 2g suggest that the modes corresponding to the long axis of the Au@Al2O3 ellipsoidal particles were located at approximately 585 nm under perpendicular excitation (θ = 90°), and the modes of the trap particle were immersed in this case. On the other hand, a broadening and redshift in the spectrum were observed under horizontal polarization (θ = 0°), due to the hybridized coupling of different modes of the trimers. The observations are basically consistent with the simulations by finite-element method (FEM) as shown in Fig. 2h. The narrowing of spectra in simulations can be explained by the differences of surface roughness and uniformity in particle size. In the simulations, a shoulder peak at 540 nm, which probably arises from the short axis mode of the Au@Al2O3 ellipsoidal particle, was observed under horizontal excitation (θ = 0°). The assignment was confirmed by evaluating the experimental and simulated plasmonic spectra of the Au-Au-Au trimers, where the Au@Al2O3 dimers were replaced by bare Au dimers (see Supplementary Fig. 5).
Figure 2i plots the electromagnetic (EM) fields around the Au@Al2O3-Au-Au@Al2O3 trimers calculated by FEM simulations. The results reveal that the ‘hotspots’ are located at the regions around the trap particle. Obvious polarization-dependent enhancement was observed with a maximum of E/E0 = 87.2 under horizontal excitation. Considering that the enhancement factor can be approximated by the fourth power of E/E0, we can estimate that the average EM enhancement around the trimer structures is on the order of 105 through simple calculation45 (maximum 5.8 × 107), representing a 102-fold increase compared with monomer arrays46,47.
SERS performance and single-molecule detection
Figure 3 illustrates the SERS performance of the Au@Al2O3-Au-Au@Al2O3 trimers. The Au-Au-Au trimers, which were similar to Au@Al2O3-Au-Au@Al2O3 in configuration but without the Al2O3 coating, were prepared for comparison. 4-Mercaptopyridine (4-Mpy), which strongly adsorbs on gold by the thiol group, was employed as a Raman probe to illustrate the chemical selectivity. As shown in Fig. 3a, the SERS signal was significantly improved on the Au@Al2O3-Au-Au@Al2O3 trimers. The improvement would be more significant with lower molecular concentrations (see Supplementary Fig. 6). It can be explained by the differences in chemical affinities between the molecules and different substrate materials. For the Au@Al2O3-Au-Au@Al2O3 trimers, the 4-Mpy molecules primarily adsorbs on the Au traps, ensuring the overlapping between the Raman probes and ‘hotspots’ in position, and thus substantially improve the SERS sensitivity. While for the Au-Au-Au trimers, 4-Mpy random adsorbs on the trimers, and the probability that a molecule is located at the hotspots is decreased. Additionally, comparative Raman mappings of 10−11 M of 4-Mpy were performed to illustrate the differences in SERS performance between the two trimer configurations, as evidenced in Supplementary Fig. 7. The impact of ALD thickness on SERS performance was also discussed in Supplementary Fig. 8.
a SERS spectra of 10-9 M 4-Mpy from the Au@Al2O3-Au-Au@Al2O3 and Au-Au-Au trimers. b SERS spectra of 10−6 M toluene from the Au@Al2O3-Au-Au@Al2O3 and Au-Au-Au trimers. c Calculated adsorption energy of 4-Mpy and toluene, respectively, on Au(111) and γ-Al2O3(100) surfaces. Au, Al and O atoms are represented in gold, gray and red colors. d–f SERS spectra of 10−14 M 4-Mpy, 10−14 M 4-MBT and 10−14 M 4-ATP from the Au@Al2O3-Au-Au@Al2O3 trimer arrays, respectively (integral time 10 s). Source data are provided as a Source Data file.
As a contrast, toluene, which is structurally similar to 4-Mpy but without the thiol group, was investigated for comparison. The results in Fig. 3b suggest that there are no distinct differences in SERS intensities between the two cases. This is because toluene adsorbs on gold and Al2O3 with similar binding affinities via a methyl group. It should be noted that the preparations for toluene and 4-Mpy were different due to their differences in binding affinities, and the real differences in SERS sensitivity would be much more significant (see Methods section, Raman preparations). Besides, Raman characterizations of 4-Mpy and toluene at different concentrations are available in Supplementary Fig. 6.
The adsorption energies of 4-Mpy and toluene on Au(111) and γ-Al2O3(100) were calculated by density functional theory (DFT) simulations, as depicted in Fig. 3c. The gold nanoparticles fabricated by e-beam evaporation preferentially expose Au(111) facets48, which is confirmed by the X-ray diffraction (XRD) and high-resolution TEM results in Supplementary Fig. 9. On the other hand, γ-Al2O3(100) was employed for the simulation due to its similarity to the amorphous and partially hydroxylated alumina produced in the ALD process49,50,51. Details are available in the Methods section, and the full simulation results are available in Supplementary Fig. 10.
The simulations reveal a strong binding affinity between 4-Mpy and Au(111) of −1.054 eV, while a significantly weaker binding affinity was observed for γ-Al2O3 (−0.455 eV). The results suggest that 4-Mpy molecules would be preferably induced to the Au trap particle in the Au@Al2O3-Au-Au@Al2O3 trimer configuration, while they would be randomly adsorbed on the surface of the Au-Au-Au trimers, illustrating the differences in SERS intensities in Fig. 3a. In comparison, the binding affinities between toluene and Au(111) and γ-Al2O3(100) are −0.380 eV and −0.307 eV, respectively, indicating that toluene weakly adsorbs on Au(111) and Al2O3 by physical adsorption with similar bonding energies. Consequently, no distinct differences in the SERS intensities in Fig. 3b is observed for toluene. Additionally, the plasmonic modes of the Au@Al2O3-Au-Au@Al2O3 trimers are relative closer to the excitation laser wavelength at 785 nm (Fig. 2 and Supplementary Fig. 5), which might be a secondary reason for the differences in SERS intensities in Fig. 3a.
Figure 3d–f presents the SERS detection limit spectra of 4-Mpy, 4-methylbenzenethiol (4-MBT) and 4-aminothiophenol (4-ATP) at a concentration of 10−14 M on the Au@Al2O3-Au-Au@Al2O3 trimers, whereas their detection limits on the Au-Au-Au trimers were determined to be 10−11 M (full data in Supplementary Figs. 6, 11). Additionally, improved signal homogeneity was observed for the Au@Al2O3-Au-Au@Al2O3 trimers, suggesting the efficiency against the heterogeneous distribution of ‘hotspots’ (Supplementary Fig. 12). The DFT simulations of different adsorption sites for these molecules are available in Supplementary Fig. 10. The experimental enhancement factor was calculated to be ≈ 1010 for 4-Mpy (see Methods section, calculation of SERS enhancement factors). Moreover, similar comparative SERS measurements of adenine, thiram, and benzeneselenol (BSe), which have a high affinity towards the gold trap particles, have also been performed to validate the functionality of the Au@Al2O3-Au-Au@Al2O3 trimers, as included in Supplementary Fig. 13.
Figure 4 illustrates the single-molecule SERS detection measurements on the Au@Al2O3-Au-Au@Al2O3 trimer arrays by the bi-analyted method. This method employs two analytes to sort out single-molecule SERS events by judging whether the event contains an individual analyte or two analytes52, and the details about the statistical method in this experiment are available in ref.53. We selected 4-MBT and 4-Mpy, which are similar in chemical structures, as the Raman probes. The concentrations were set to be 10−13 M, and the Raman intensities at 1078 cm−1 (4-MBT) and 1098 cm−1 (4-Mpy) were analyzed to evaluate the SERS performance. Figure 4a plots the statistical map from 1640 measurement points, where pure 4-MBT events, pure 4-Mpy events and mixed events are marked with different colors. Here most of the events were blank due to the low molecular concentrations, which is favorable to improve the validity of single-molecule SERS53,54. Fig. 4b presents the typical SERS spectra of single-molecule 4-MBT events, single-molecule 4-Mpy events, mixed events and null events. Figure 4c records the statistic results from the map, including 52 pure 4-Mpy events, 48 pure 4-MBT events, and 9 mix events possessing Raman characters from both molecules. Rigorous statistical histogram of the single-molecule frequency by modified principal-component analysis (MPCA) algorithm was plotted in Fig. 4d (details see Supplementary Fig. 14 and Methods section, computational steps for MPCA algorithm). The edge of the histogram indicates a high probability of single-molecule events. It can be observed that the contributions of p ≈ 1 (4-Mpy event) and p ≈ 0 (4-MBT event) are very close because of their similarity in Raman scattering cross sections. Moreover, single-molecule characteristics including signal blinking and spectrum wandering were investigated (see Supplementary Fig. 15), further identifying the validity of the single-molecule SERS events.
a 2D statistical map of the single-molecule 4-MBT events, 4-Mpy events and mixed events by the bi-analyte method (40 × 41, step 1.5 μm, integral time 500 ms). b Typical SERS spectra of single-molecule 4-MBT events (purple), single-molecule 4-Mpy events (brown), mixed events (blue) and null events (pink). c Statistical histograms of pure 4-Mpy events (brown), mixed events (bule) and pure 4-MBT events (purple). d Probability histogram of the pure 4-Mpy events obtained by MPCA algorithm. Source data are provided as a Source Data file.
Pathological diagnosis and subtyping of lung tumors
For lung cancer patients, the balances of oxygen free radical breakdown, leading to the lipid peroxidation of polyunsaturated fatty acids in cancer cell membranes and organelle membranes, and consequently extra production of aldehydes and other volatile organic compounds (VOCs)55,56,57. As a result, patients with lung cancer may exhibit significantly higher levels of aldehydes in their lung tissues58,59,60. While SERS measurement of aldehyde molecules has been showcased with exhaled breath condensate from patients61,62, conducting direct SERS analysis with human tissues remains challenging due to the limited quantity of aldehydes within cells. In-depth investigations, including methods for assessing the accuracy of SERS results with tissue biopsy data, exploring the relationship between TNM stage and SERS outcomes, and investigating the possibility of tumor subtyping by SERS, remains to be answered.
Leveraging the sensitivity of the Au@Al2O3-Au-Au@Al2O3 trimers, SERS investigations with human tissues were conducted to demonstrate their potential for the early diagnosis and subtyping of lung tumors, as depicted in Fig. 5. We prepared 4-ATP-modified Au@Al2O3-Au-Au@Al2O3 samples for the detection of aldehyde molecules. A monolayer of 4-ATP was adsorbed on the gold trap particle via its thiol group during preparations. The amino group located at the opposite end of 4-ATP reacts with aldehydes to form a C=N bond for Raman identification55,63, as illustrated in Fig. 5a. Typical Raman spectra from the 4-ATP-modified sample before and after benzaldehyde (BA) collection were displayed in Fig. 5b, where the mode at 1623 cm−1 suggesting the C=N vibration mode can be clearly discerned after the collection64,65. The SERS optimizations for the experiment are available in Supplementary Fig. 16, with a detection limit of 10−9 M for BA, as shown in Supplementary Fig. 17. Additionally, SERS detection of other aldehydes are presented in Supplementary Fig. 18. The anti-interference performance of the Au@Al2O3-Au-Au@Al2O3 trimer samples were displayed in Fig. 5c, suggesting the ability in specific detection of aldehyde molecules.
a Schematic diagram of the reaction between aldehydes and 4-ATP on gold. b SERS spectra of 4-ATP on Au@Al2O3-Au-Au@Al2O3 trimers before (violet) and after (orange) reacting with discharged gas containing BA molecules. The C=N vibration mode suggesting the reaction is marked with a light green strip. c Anti-interference test of the Au@Al2O3-Au-Au@Al2O3 trimer samples exposed to BA, acetone, methanol, ethanol, acetonitrile, ethyl acetate, hexyl hydride and water. d, e Optical images of the ad-ca and sq-ca lung tumor tissues, respectively, after HE staining under a microscope. The scale bars are 50 μm. This experiment was independently repeated for all the tumor samples, and the results were similar. f Typical SERS spectra from the samples containing fresh ad-ca (red) or sq-ca cancer (violet) tissues, and blank sample (brown). g, h Raman mapping at 1623 cm−1 from the ad-ca and sq-ca samples (1600 points), respectively (step 1.5 μm, integral time 10 s), which color scales representing Raman intensities. Source data are provided as a Source Data file.
Further investigations were performed with fresh lung cancer tissue of different subtypes, as illustrated in Fig. 5d–h. Lung tumors are generally divided into adenocarcinoma (ad-ca), squamous carcinoma (sq-ca), and other minor subtypes58. We obtained ten fresh lung tumor tissues from patients by surgical operation. The tissues were cut into dimensions of approximately 1 × 1 × 0.5 cm3 for SERS investigations. The typical pathological characterizations of cancer cells from the two major subtypes after hematoxylin-eosin (HE) staining are shown in Fig. 5d, e. The 4-ATP modified trimer samples were immersed in buffer solution containing tumor tissues (Supplementary Fig. 19). We collected 1600 Raman spectra from each sample. The averaged SERS spectra from an ad-ca sample and a sq-ca sample are compared in Fig. 5f, suggesting that the signal intensity for ad-ca was much stronger than that for sq-ca. Corresponding Raman intensity maps are plotted in Fig. 5g, h, revealing that a majority of the measurement points was positive for ad-ca, while only a few events were positive for sq-ca.
We analyzed the SERS results from the ten patients, including six ad-ca, three sq-ca, and one benign case (Supplementary Fig. 20), and compared the results with their TNM stage (Supplementary Table 1). Some preliminary conclusions were drawn: 1) SERS is sensitive in distinguishing different lung tumor subtypes, suggesting variations in the body content of aldehyde molecules among them. Specifically, SERS is sensitive to ad-ca but not to sq-ca or benign cases. 2) There is no evidence suggesting a correlation between the SERS outcomes and the original tumor size or lymph node with the same volume of tumor tissue. For sq-ca patients, SERS diagnosis is appliable to all the patients with TNM stages from IA1 to IIB. Still, further studies with a larger dataset are required to refine these preliminary observations. Similar Raman measurement of ad-ca has also been also performed on the Au-Au-Au trimers for comparison, as revealed in Supplementary Fig. 21.
Discussion
In summary, this study presents an approach to fabricate large-area nanoarrays composed of orientated plasmonic trimers. These trimers comprise a pair of plasmonic dimers with a trap particle positioned in between, selectively guiding probe molecules to the trap through chemical affinity. This configuration facilitates spatial overlap between the molecular adsorption sites and plasmonic ‘hotspots’ and enhances the probability that probe molecules experiencing the amplification from ‘hotspots’, offering a robust approach to improve SERS sensitivity against the heterogeneous ‘hotspots’. We prepared the Au@Al2O3-Au-Au@Al2O3, Au-Au-Au, and other different types of trimers. The material of the plasmonic trimers can be modulated during the preparations, allowing on-demand construction of trimers with different compositions.
Benefiting from the trapping effects and small gap distances of the trimers, SERS performance was achieved. The sensitivity was demonstrated by comparing the SERS performance of the Au@Al2O3-Au-Au@Al2O3 and Au-Au-Au trimers using different molecules, including thiols, amines, disulfides and selenols, as evidenced by DFT calculations. Moreover, single-molecule sensitivity was demonstrated with the bi-analyte method, further highlighting the SERS performance of the trimers.
The trimers were further applied in the pathological diagnosis of lung tumors. Leveraging the sensitivity of the trimers, SERS investigations were conducted with fresh lung tumor tissues, where the concentration of probe molecules is low. Our findings indicate that SERS is sensitive to ad-ca tumors, but not sq-ca or benign cases tumors, demonstrating the potential of SERS for the early diagnosis and subtyping of lung tumors. By addressing the crucial challenge posed by the heterogeneous distribution of ‘hotspots’, our approach offers an approach to explore the full potential of SERS in various applications.
Methods
Materials and chemicals
Au (99.999%), Ag (99.999%), titanium oxide (99.99%) and aluminum foil (99.999%) were purchased from Zhong Nuo Advanced Material Technology Co., Ltd (Beijing, China). The ALD precursor of trimethylaluminum (99.999%) and water (>18.2 MΩ cm) were purchased from Jiangsu MNT Micro and Nanotech Co, Ltd. Polymethyl methacrylate (PMMA) was purchased from MicroChem (950PMMA A4). Phosphoric acid (85 wt.%), perchloric acid (≥99.7%), oxalic acid (99%), chromic acid (5 wt.%), copper(II) chloride dihydrate (≥99.7%), acetone (≥99.7%), absolute ethanol (≥99.7%), 4-methylbenzenethiol (4-Mpy, 90%), 4-mercaptopyridine (4-MBT, 96%), 4-aminothiophenol (4-ATP, 90%), adenine (≥99.5%), thiram (97%), benzeneselenol (BSe, 97%), toluene (≥99.7%), 4-ethylbenzaldehyde (99.0%), 2-furaldehyde (99.0%), salicylaldehyde (99.0%), and benzaldehyde (99.0%) were purchased from Aladdin Biochemical Technology. All the reagents were used as received without further purification. Milli-Q water (>18.2 MΩ cm) was utilized in all experiments.
Preparations of the AAO membranes
Briefly, electrochemically polished aluminum foils were anodized in 0.3 M oxalic acid at 40 V and 0 °C to fabricate the porous AAO membrane by a two-step anodization method44. The thickness of the fabricated membranes was 300 nm, the diameter of the pores was about 30 nm, and the center-to-center spacing between two adjacent pores was 100 nm. The fabricated AAO membranes were immersed in 5 wt.% phosphoric acid at 30 °C for 26 min to broaden the pore diameter. The broadened samples were spin-coated with PMMA at 1200 rpm for 60 s, and baked at 120 °C for 10 min. The AAO membranes were peeled off from the aluminum foil in CuCl2 solution (10 wt.%), and transferred onto phosphoric acid solution (5 wt.%) at 30 °C for 36 min to further adjust the membrane thickness. Afterwards, the membranes were immersed in acetone to remove PMMA, and then transferred onto SiO2/Si wafers. The final thickness of the membrane was about 240 nm, and the pore diameter was 80 nm.
Fabrication of the trimer arrays
First, the dimer particles were fabricated by angle-resolved shadow deposition using AAO membranes66. The e-beam deposition was conducted at 7 × 10−4 Pa and 0.1 nm s−1 (Beijing Technol Science Co., Ltd). The deposition thicknesses were 35 nm, and the deposition angles for the first and second depositions were 8.7° and 7.9°, respectively. The AAO pores were partially blocked during the evaporations. Adjustments were made for the second deposition due to changes in pore diameters after the initial evaporation. Subsequently, a 1.5 nm thick Al2O3 layer was grown on the Au dimers by ALD (Jiangsu MNT Micro and Nanotech Co, Ltd.) according to ref.67. The ALD process is optional depending on the requirement. The diameter of the AAO pores was further adjusted to approximately 10 nm by magnetron sputtering (Beijing Chuangshiweina Technology Co., Ltd.). Following this, the trap particle was vertically deposited on the sample by e-beam deposition with a thickness of 20 nm. Ultimately, the trimer arrays were obtained by removing the AAO membranes with adhesive tape.
Characterizations
The SEM images were obtained by FEI Inspect F50. The TEM images and elemental mappings were obtained by Thermo Fisher Talos F200X. The particles were transferred onto copper grids substrate by PMMA before TEM characterizations. The XRD patterns were obtained by a Rigaku Smartlab (3). The UV-vis spectra were collected by a HITACHI U-3900 spectrometer. The Raman spectra were collected by XploRA PLUS (HORIBA) with a 785 nm laser (spot diameter ≈ 1 μm), 100× objective (power density 0.5 mW), and 600 grooves mm−1 grating. The images of the cancer cells were captured under a 40× optical microscope (OLYMPUS).
Raman preparations
For 4-MBT, 4-Mpy, 4-ATP, thiram and BSe, as well as the mixture solution of 4-MBT and 4-Mpy, the SERS substrates were immersed in a 10 mL ethanol solution for 4 h for molecular adsorption, rinsed with ethanol and dried with nitrogen gas. For the treatment of adenine, the ethanol solution was replaced by an aqueous solution with all other conditions remaining constant. In the case of toluene, the substrates were immersed in a 10 mL solution for 4 h and directly dried with nitrogen gas, as toluene would be easily washed away due to its weak bonding with the substrates. In VOCs detection, the samples were modified with 10−6 M 4-ATP, and then placed in a closed container containing fresh lung cancer tissue in phosphate buffer (1× pH 7.4) at 55 °C for 30 min (see Supplementary Fig. 16). Fresh lung tumors tissues were provided by the Affiliated Hospital of Qingdao University from surgical operations. The tissues were cut into 1 × 1 × 0.5 cm3 fragments and immersed in sterile Earle’s balanced buffer solution before SERS measurement. This study was approved by the Ethics Committee of the Affiliated Hospital of Qingdao University. All participates had signed the consent form. All methods were carried out in accordance with relevant guidelines and regulations. Informed consent was obtained from all subjects and/or their legal guardians.
FEM simulations
The finite-element method (FEM) simulations were carried by COMSOL Multiphysics software. The excitation light is a linearly polarized plane wave perpendicular to the x-y plane. The complex refractive index (n + ik) of gold and aluminum oxide were obtained from the literature68,69. Scattering boundary conditions were applied to define the boundary. Periodic boundary conditions were employed, utilizing a lattice with a center-to-center distance of 100 nm, in reference to the AAO membrane lattice.
The parameters for FEM simulations were derived from statistical results obtained by TEM characterizations. For the Au@Al2O3-Au-Au@Al2O3 trimers, the long and short axes of the Au@Al2O3 ellipsoid are approximately 43 nm and 34 nm, respectively. The long and short axes of the trap particle are about 18 and 16 nm, respectively, with a statistical error of approximately 1-2 nm. The thickness of the Al2O3 coating is 1.5 nm ± 0.1 nm, and the gap between two adjacent particles is approximately 2 nm. The particles were modeled as 3D ellipsoids, and the height of the ellipsoidal dimer particles and the trap particle was set to 35 and 20 nm, respectively, in accordance with the e-beam evaporation parameters. Similar parameters were applied for the Au-Au-Au trimers, with the exception of the absence of the Al2O3 coating.
DFT simulations
The DFT calculations were performed using the Vienna ab-initio simulation package (VASP) with projector augmented wave (PAW) method. The Perdew–Burke–Ernzerhof (PBE) exchange-correlation energy function was applied within the generalized gradient approximation (GGA). A cut-off energy of 500 eV for the plane-wave basis restriction was employed in all calculations, with a convergence criterion for the electronic self-consistent iteration set to be 10−5 eV. Gamma-only point sampling was used for Brillouin zone integration during structure optimization. The geometry was fully relaxed without constraints until the force on each atom was less than 0.05 eV Å−1. Grimme’s DFT-D3 correction was incorporated to account for dispersion interactions. The slab model of Au(111) was generated based on the optimized crystal structure, with a vacuum layer of 15 Å introduced to ensure separation between slabs. The adsorption energy (Eads) of an adsorbate A was defined as Eq. (1):
where EA+surf, Esurf, and EA are the total energy of surface system, the energy of the surface slab, and the energy of adsorbate, respectively.
During the ALD process, amorphous and partially hydroxylated Al2O3 layers are deposited. In this study, γ-Al2O3 was employed for simulation due to its similarity to the alumina produced in the ALD process, exhibiting a poor crystalline nature49,50. Additionally, γ-Al2O3 shares similarities with amorphous alumina in having both 4-coordinated and 6-coordinated aluminum.
The crystallographic directions of γ-Al2O3 are typically given within the spinel orientation. Therefore, its thermodynamically most stable (100) surface within the spinel orientation was created from the γ-Al2O3 unit cell by adding a vacuum gap in the z-direction51. For the current calculations, an 8.4 Å × 16.1 Å × 20.8 Å box containing partially hydroxylated aluminum oxide layers was utilized70. The bottom 16 Al and 24 O atoms were kept fixed, while the top atoms of the slab and all the atoms of the adsorbed species were allowed to relax. This configuration includes terminal hydroxyl, bridge hydroxyl, and bridge oxygen on the surface. The adsorption modes of 4-MBT, 4-Mpy, 4-ATP, and toluene on 4- and 6-coordinated aluminum were considered, and the final results represent the most stable adsorption mode after optimization.
Calculation of SERS enhancement factors
The experimental SERS enhancement factor was calculated according to Eq. (2)1:
Where ISERS and IRS are the SERS spectral intensity and intrinsic Raman spectral intensity, respectively, and cSERS and cRS are the corresponding molecular concentrations. Taking the Raman mode of 4-Mpy at 1098 cm−1 as an example (10−14 M, data extracted from Fig. 3), the EF of the Au@Al2O3-Au-Au@Al2O3 trimers was calculated to be ≈ 1010.
Computational steps for MPCA algorithm
The steps of MPCA follow a standard method71,72: (1) 1640 Raman spectra were recorded, and 43 data points at the range of 1050–1120 cm−1 of each spectrum were selected to define a matrix M of T × N (1640 × 43); (2) Subtract the mean intensity from each row of matrix M to obtain matrix M′; (3) The covariance matrix V (N × N) of the matrix M′, and the eigenvalues and eigenvectors of the matrix V were calculated (Supplementary Fig. 14a). The first two eigenvectors in the statistical row of the dual analysis method are the dominating components; (4) A coefficient matrix C was obtained by operation, which is equivalent to the scalar product of the spectra and the first two eigenvectors. The matrix C was plotted in two-dimensional spatial coordinates (Supplementary Fig. 14b). Each point in the graph represents an event, with pure spectral events appearing on both the 4-MBT and 4-Mpy axes, null events near the origin, and mixed events appearing in the middle of the two axes; (5) Finally, linear transformation is employed to relocate the coordinates of the two axes in space. After removing the noise of the null event, the single-molecule probability histogram p was defined as Eq. (3):
The (x, y) are obtained through the original coordinates (Supplementary Fig. 14b). The histogram shows the contribution of different spectral events to the total number of spectra except for the null event.
Reporting summary
Further information on research design is available in the Nature Portfolio Reporting Summary linked to this article.
Data availability
The data that support the findings of this study are available from the corresponding author upon request. Source data are provided with this paper.
References
Leong, S. X. et al. Noninvasive and Point-of-Care Surface-Enhanced Raman Scattering (SERS)-Based Breathalyzer for Mass Screening of Coronavirus Disease 2019 (COVID-19) under 5 min. ACS Nano 16, 2629–2639 (2022).
Langer, J. et al. Present and Future of Surface-Enhanced Raman Scattering. ACS Nano 14, 28–117 (2020).
Fan, X. et al. Hotspots on the Move: Active Molecular Enrichment by Hierarchically Structured Micromotors for Ultrasensitive SERS Sensing. ACS Appl. Mater. Interfaces 12, 28783–28791 (2020).
Zong, C. et al. Surface-Enhanced Raman Spectroscopy for Bioanalysis: Reliability and Challenges. Chem. Rev. 118, 4946–4980 (2018).
Ge, M. et al. General Surface-Enhanced Raman Spectroscopy Method for Actively Capturing Target Molecules in Small Gaps. J. Am. Chem. Soc. 143, 7769–7776 (2021).
Ding, Q. et al. Quantitative and Sensitive SERS Platform with Analyte Enrichment and Filtration Function. Nano Lett. 20, 7304–7312 (2020).
Wang, Y.-H. et al. In situ Raman spectroscopy reveals the structure and dissociation of interfacial water. Nature 600, 81–85 (2021).
Xie, W. & Schlücker, S. Hot electron-induced reduction of small molecules on photorecycling metal surfaces. Nat. Commun. 6, 7570 (2015).
Wei, Y. et al. Probing Oxidation Mechanisms in Plasmonic Catalysis: Unraveling the Role of Reactive Oxygen Species. Nano Lett. 24, 2110–2117 (2024).
Tang, X. et al. Exploring and Engineering 2D Transition Metal Dichalcogenides toward Ultimate SERS Performance. Adv. Mater. 36, 2312348 (2024).
Ma, H. et al. Rapidly determining the 3D structure of proteins by surface-enhanced Raman spectroscopy. Sci. Adv. 9, eadh8362 (2023).
Huang, J. et al. Multiplexed Discrimination of Single Amino Acid Residues in Polypeptides in a Single SERS Hotspot. Angew. Chem. Int. Ed. 59, 11423–11431 (2020).
Le Ru, E. C., Etchegoin, P. G. & Meyer, M. Enhancement factor distribution around a single surface-enhanced Raman scattering hotspot and its relation to single molecule detection. J. Chem. Phys. 125, 204701 (2006).
Xu, H., Bjerneld, E. J., Käll, M. & Börjesson, L. Spectroscopy of Single Hemoglobin Molecules by Surface Enhanced Raman Scattering. Phys. Rev. Lett. 83, 4357–4360 (1999).
Nie, S. & Emory, S. R. Probing Single Molecules and Single Nanoparticles by Surface-Enhanced Raman Scattering. Science 275, 1102–1106 (1997).
Kneipp, K. et al. Single Molecule Detection Using Surface-Enhanced Raman Scattering (SERS). Phys. Rev. Lett. 78, 1667–1670 (1997).
Fang, Y., Seong, N.-H. & Dlott, D. D. Measurement of the Distribution of Site Enhancements in Surface-Enhanced Raman Scattering. Science 321, 388–392 (2008).
Son, J. et al. Toward Quantitative Surface-Enhanced Raman Scattering with Plasmonic Nanoparticles: Multiscale View on Heterogeneities in Particle Morphology, Surface Modification, Interface, and Analytical Protocols. J. Am. Chem. Soc. 144, 22337–22351 (2022).
Kim, J. et al. Polymorphic Assembly from Beveled Gold Triangular Nanoprisms. Nano Lett. 17, 3270–3275 (2017).
Matricardi, C. et al. Gold Nanoparticle Plasmonic Superlattices as Surface-Enhanced Raman Spectroscopy Substrates. ACS Nano 12, 8531–8539 (2018).
Zhao, X. et al. Plasmon-exciton coupling by hybrids between graphene and gold nanorods vertical array for sensor. Appl. Mater. Today 14, 166–174 (2019).
Dong, J. et al. Flexible and transparent Au nanoparticle/graphene/Au nanoparticle ‘sandwich’ substrate for surface-enhanced Raman scattering. Mater. Today Nano 9, 100067 (2020).
Cao, Y. & Sun, M. Tip-enhanced Raman spectroscopy. Rev. Phys. 8, 100067 (2022).
Xu, J. et al. Determining structural and chemical heterogeneities of surface species at the single-bond limit. Science 371, 818–822 (2021).
Huang, T.-X. et al. Probing the edge-related properties of atomically thin MoS2 at nanoscale. Nat. Commun. 10, 5544 (2019).
Zrimsek, A. B. et al. Single-Molecule Chemistry with Surface- and Tip-Enhanced Raman Spectroscopy. Chem. Rev. 117, 7583–7613 (2017).
Zhang, R. et al. Chemical mapping of a single molecule by plasmon-enhanced Raman scattering. Nature 498, 82–86 (2013).
Kim, N. H. et al. Smart SERS Hotspots: Single Molecules Can Be Positioned in a Plasmonic Nanojunction Using Host–Guest Chemistry. J. Am. Chem. Soc. 140, 4705–4711 (2018).
Choi, H.-K. et al. Metal-Catalyzed Chemical Reaction of Single Molecules Directly Probed by Vibrational Spectroscopy. J. Am. Chem. Soc. 138, 4673–4684 (2016).
Chikkaraddy, R. et al. Single-molecule strong coupling at room temperature in plasmonic nanocavities. Nature 535, 127–130 (2016).
Mubeen, S. et al. Plasmonic Properties of Gold Nanoparticles Separated from a Gold Mirror by an Ultrathin Oxide. Nano Lett. 12, 2088–2094 (2012).
Li, C.-Y. et al. In situ probing electrified interfacial water structures at atomically flat surfaces. Nat. Mater. 18, 697–701 (2019).
Li, J. F. et al. Shell-isolated nanoparticle-enhanced Raman spectroscopy. Nature 464, 392–395 (2010).
Pazos-Perez, N. et al. Organized Plasmonic Clusters with High Coordination Number and Extraordinary Enhancement in Surface-Enhanced Raman Scattering (SERS). Angew. Chem. Int. Ed. 51, 12688–12693 (2012).
Braun, G. et al. Chemically Patterned Microspheres for Controlled Nanoparticle Assembly in the Construction of SERS Hotspots. J. Am. Chem. Soc. 129, 7760–7761 (2007).
Kasera, S., Biedermann, F., Baumberg, J. J., Scherman, O. A. & Mahajan, S. Quantitative SERS Using the Sequestration of Small Molecules Inside Precise Plasmonic Nanoconstructs. Nano Lett. 12, 5924–5928 (2012).
Taylor, R. W. et al. Precise Subnanometer Plasmonic Junctions for SERS within Gold Nanoparticle Assemblies Using Cucurbit[n]uril “Glue”. ACS Nano 5, 3878–3887 (2011).
Song, X. et al. Sub-1.5 nm-gapped heterodimeric plasmonic nanomolecules. Chem. Sci. 13, 4788–4793 (2022).
Tapio, K. et al. A Versatile DNA Origami-Based Plasmonic Nanoantenna for Label-Free Single-Molecule Surface-Enhanced Raman Spectroscopy. ACS Nano 15, 7065–7077 (2021).
Lim, D.-K., Jeon, K.-S., Kim, H. M., Nam, J.-M. & Suh, Y. D. Nanogap-engineerable Raman-active nanodumbbells for single-molecule detection. Nat. Mater. 9, 60–67 (2010).
Fang, W. et al. Quantizing single-molecule surface-enhanced Raman scattering with DNA origami metamolecules. Sci. Adv. 5, eaau4506 (2019).
Kasera, S. et al. Quantitative multiplexing with nano-self-assemblies in SERS. Sci. Rep. 4, 6785 (2014).
Hao, Q. et al. VO2/TiN Plasmonic Thermochromic Smart Coatings for Room-Temperature Applications. Adv. Mater. 30, 1705421 (2018).
Hao, Q. et al. Facile design of ultra-thin anodic aluminum oxide membranes for the fabrication of plasmonic nanoarrays. Nanotechnology 28, 105301 (2017).
Charconnet, M. et al. Generalization of Self‐Assembly Toward Differently Shaped Colloidal Nanoparticles for Plasmonic Superlattices. Small Methods 7, 2201546 (2023).
Li, G. et al. Quantitative SERS Analysis by Employing Janus Nanoparticles with Internal Standards. Adv. Mater. Interfaces 10, 2202127 (2023).
Le Ru, E. C. & Etchegoin, P. G. Single-Molecule Surface-Enhanced Raman Spectroscopy. Annu. Rev. Phys. Chem. 63, 65–87 (2012).
Wei, Y. et al. Investigation of the Plasmon-Activated C–C Coupling Reactions by Liquid-State SERS Measurement. ACS Appl. Mater. Interfaces 14, 54320–54327 (2022).
Tai, T. B. et al. Atomic Layer Deposition of Al2O3 Using Aluminum Triisopropoxide (ATIP): A Combined Experimental and Theoretical Study. J. Phys. Chem. C. 123, 485–494 (2019).
Réocreux, R. et al. Reactivity of shape-controlled crystals and metadynamics simulations locate the weak spots of alumina in water. Nat. Commun. 10, 3139 (2019).
Sandupatla, A. S., Alexopoulos, K., Reyniers, M.-F. & Marin, G. B. Ab Initio Investigation of Surface Chemistry of Alumina ALD on Hydroxylated γ-Alumina Surface. J. Phys. Chem. C. 119, 13050–13061 (2015).
Le Ru, E. C., Meyer, M. & Etchegoin, P. G. Proof of Single-Molecule Sensitivity in Surface Enhanced Raman Scattering (SERS) by Means of a Two-Analyte Technique. J. Phys. Chem. B 110, 1944–1948 (2006).
Hao, Q. et al. Verification and Analysis of Single-Molecule SERS Events via Polarization-Selective Raman Measurement. Anal. Chem. 94, 1046–1051 (2022).
Zrimsek, A. B., Wong, N. L. & Van Duyne, R. P. Single Molecule Surface-Enhanced Raman Spectroscopy: A Critical Analysis of the Bianalyte versus Isotopologue Proof. J. Phys. Chem. C. 120, 5133–5142 (2016).
Qiao, X. et al. Selective Surface Enhanced Raman Scattering for Quantitative Detection of Lung Cancer Biomarkers in Superparticle@MOF Structure. Adv. Mater. 30, 1702275 (2018).
Hakim, M. et al. Volatile Organic Compounds of Lung Cancer and Possible Biochemical Pathways. Chem. Rev. 112, 5949–5966 (2012).
Peng, G. et al. Diagnosing lung cancer in exhaled breath using gold nanoparticles. Nat. Nanotech. 4, 669–673 (2009).
Jia, Z. et al. Detection of Lung Cancer: Concomitant Volatile Organic Compounds and Metabolomic Profiling of Six Cancer Cell Lines of Different Histological Origins. ACS Omega 3, 5131–5140 (2018).
Fuchs, P., Loeseken, C., Schubert, J. K. & Miekisch, W. Breath gas aldehydes as biomarkers of lung cancer. Int. J. Cancer 126, 2663–2670 (2009).
Bajtarevic, A. et al. Noninvasive detection of lung cancer by analysis of exhaled breath. BMC Cancer 9, 348 (2009).
Li, A., Qiao, X., Liu, K., Bai, W. & Wang, T. Hollow Metal Organic Framework Improves the Sensitivity and Anti‐Interference of the Detection of Exhaled Volatile Organic Compounds. Adv. Funct. Mater. 32, 2202805 (2022).
Xia, Z., Li, D. & Deng, W. Identification and Detection of Volatile Aldehydes as Lung Cancer Biomarkers by Vapor Generation Combined with Paper-Based Thin-Film Microextraction. Anal. Chem. 93, 4924–4931 (2021).
Qiao, X. et al. Detection of Exhaled Volatile Organic Compounds Improved by Hollow Nanocages of Layered Double Hydroxide on Ag Nanowires. Angew. Chem. Int. Ed. 58, 16523–16527 (2019).
Lee, M. et al. Applicability of laser‐induced Raman microscopy for in situ monitoring of imine formation in a glass microfluidic chip. J. Raman Spectrosc. 34, 737–742 (2003).
Kozhevina, L. I., Prokopenko, E. B., Rybachenko, V. I. & Titov, E. V. Interpretation of the vibrational spectrum of benzylideneaniline. J. Appl. Spectrosc. 59, 805–809 (1993).
Hao, Q. et al. Controlled Patterning of Plasmonic Dimers by Using an Ultrathin Nanoporous Alumina Membrane as a Shadow Mask. ACS Appl. Mater. Interfaces 9, 36199–36205 (2017).
Tang, X. et al. Electromagnetic Mechanisms or Chemical Mechanisms? Role of Interfacial Charge Transfer in the Plasmonic Metal/Semiconductor Heterojunction. J. Phys. Chem. Lett. 13, 7816–7823 (2022).
Rakić, A. D., Djurišić, A. B., Elazar, J. M. & Majewski, M. L. Optical properties of metallic films for vertical-cavity optoelectronic devices. Appl. Opt. 37, 5271 (1998).
Zhukovsky, S. V. et al. Experimental Demonstration of Effective Medium Approximation Breakdown in Deeply Subwavelength All-Dielectric Multilayers. Phys. Rev. Lett. 115, 177402 (2015).
Eng, P. J. et al. Structure of the Hydrated α-Al2O3 (0001) Surface. Science 288, 1029–1033 (2000).
Etchegoin, P. G., Meyer, M., Blackie, E. & Le Ru, E. C. Statistics of Single-Molecule Surface Enhanced Raman Scattering Signals: Fluctuation Analysis with Multiple Analyte Techniques. Anal. Chem. 79, 8411–8415 (2007).
Tiwari, S., Khandelwal, U., Sharma, V. & Kumar, G. V. P. Single Molecule Surface Enhanced Raman Scattering in a Single Gold Nanoparticle-Driven Thermoplasmonic Tweezer. J. Phys. Chem. Lett. 12, 11910–11918 (2021).
Acknowledgements
Q.H. acknowledges the National Natural Science Foundation of China (Grant No. 22004016) and the Open Research Fund of Key Laboratory of Quantum Materials and Devices (Southeast University), Ministry of Education. T.Q. acknowledges the National Natural Science Foundation of China (Grant No. 12374370). X.F. acknowledges the Natural Science Foundation of Jiangsu Province (Grant No. BK20230807) and China Postdoctoral Science Foundation Funded Project (Grant No. 2021M700773). The authors acknowledge Southeast University and Key Laboratory of Quantum Materials and Devices of Ministry of Education for the technique support in simulations.
Author information
Authors and Affiliations
Contributions
Q.H. provided the original idea. Q.H. and T.Q. jointly supervised the project. X.Z. carried out the design of the experiment, prepared the measurements, and wrote the manuscript. X.L. and G.S. provided the lung tumor tissues and pathological analysis. X.F., X.T., M.L., L.Y., Y.W., W.S., Z.S. and Z.Z. participated in the characterizations and discussions. D.C., G.L. and X.N.Z. provided DFT and FEM simulation calculations, respectively. Q.H. corrected the manuscript. All authors have approved the final manuscript.
Corresponding authors
Ethics declarations
Competing interests
The authors declare no competing interests.
Peer review
Peer review information
Nature Communications thanks the anonymous reviewers for their contribution to the peer review of this work. A peer review file is available.
Additional information
Publisher’s note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Supplementary information
Source data
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Zhao, X., Liu, X., Chen, D. et al. Plasmonic trimers designed as SERS-active chemical traps for subtyping of lung tumors. Nat Commun 15, 5855 (2024). https://doi.org/10.1038/s41467-024-50321-0
Received:
Accepted:
Published:
DOI: https://doi.org/10.1038/s41467-024-50321-0
This article is cited by
-
Rapid and sensitive detection of malachite green by multifunctional octahedron UiO- 66-NH2/Fe3O4/Ag SERS substrate
Microchimica Acta (2025)
-
Electromagnetic field-charge transfer synergy boosted SERS in noble metal–semiconductor nanohybrids for environmental and bio-detection
Rare Metals (2025)
-
Nanopores-coupled SERS platforms on superslippery surfaces using Au&Ag alloy pillars for biomolecules enrichment and detection
Rare Metals (2025)