Abstract
Purpose
A teaching model for trabeculectomy is described using pig eyes prepared in formalin.
Method
The model enables trainee surgeons to practice various aspects of tissue handling required for successful trabeculectomy including the construction of a fornix-based conjunctival flap, scleral flap with buried releasable sutures, and water-tight conjunctival closure.
Results
Exposure to the necessary skills required to perform trabeculectomy surgery can be improved by the use of wet laboratory practice.
Conclusions
Trabeculectomy surgery experience is becoming more limited as fewer procedures are being performed due to the efficacy of recent medications. Wet laboratories will become an increasingly important aspect of a comprehensive ophthalmology training programme.
Similar content being viewed by others
Log in or create a free account to read this content
Gain free access to this article, as well as selected content from this journal and more on nature.com
or
References
Cairns JE . Trabeculectomy. Preliminary report of a new method. Am J Ophthalmol 1968; 66: 673–679.
Sadun AA . The challenge of teaching ophthalmology: a Residency Review Committee perspective. Ophthalmology 2000; 107: 1971–1972.
Keltner JL . Four years of ophthalmology training. Has its time come? Arch Ophthalmol 1990; 108: 35–37.
Parke II DW . Should postresidency fellowships be mandatory? Arch Ophthalmol 1990; 108: 37–39.
Liesegang TJ, Hoskins Jr HD, Albert DM, O'Day DM, Spivey BE, Sadun AA et al. Ophthalmic education: where have we come from, and where are we going? Am J Ophthalmol 2003; 136: 114–121.
Parrish II RK . The future of ophthalmology residency training programs. Ophthalmic Surg 1994; 25: 500–503.
Rowden A, Krishna R . Resident cataract surgical training in United States residency programs. J Cataract Refract Surg 2002; 28: 2202–2205.
Gibson A, Boulton M, Watson M, Fielder A . Surgical training in ophthalmology. Lancet 2002; 360: 1702.
Morrell AJ, Searle AE, O'Neill EC . Trabeculectomy as an introduction to intraocular surgery in an ophthalmic training program. Ophthalmic Surg 1989; 20: 557–560.
Edmunds B, Bunce CV, Thompson JR, Salmon JF, Wormald RP . Factors associated with success in first-time trabeculectomy for patients at low risk of failure with chronic open-angle glaucoma. Ophthalmology 2004; 111: 97–103.
Paikal D, Yu F, Coleman AL . Trends in glaucoma surgery incidence and reimbursement for physician services in the Medicare population from 1995 to 1998. Ophthalmology 2002; 109: 1372–1376.
Auffarth GU, Wesendahl TA, Solomon KD, Brown SJ, Apple DJ . A modified preparation technique for closed-system ocular surgery of human eyes obtained postmortem: an improved research and teaching tool. Ophthalmology 1996; 103: 977–982.
Swinger CA, Kornmehl EW . Dehydration of post-mortem eyes for practice and experimental surgery. Ophthalmic Surg 1985; 16: 182–183.
Borirak-chanyavat S, Lindquist TD, Kaplan HJ . A cadaveric eye model for practicing anterior and posterior segment surgeries. Ophthalmology 1995; 102: 1932–1935.
Castellano D, Spraul J, Whitaker TE . A simple, cost-effective method for practicing phacoemulsification in the cadaveric eye. Ophthalmic Surg Lasers 1998; 29: 253–256.
Lenart TD, McCannel CA, Baratz KH, Robertson DM . A contact lens as an artificial cornea for improved visualization during practice surgery on cadaver eyes. Arch Ophthalmol 2003; 121: 16–19.
Oram O, Gross RL, Severin TD, Feldman RM, Orengo-Nania S . A human cadaver eye model for anterior and posterior segment laser applications. Ophthalmic Surg 1994; 25: 449–451.
Rootman DS, Marcovich A . Utilizing eye bank eyes and keratoplasty techniques to teach phacoemulsification. Ophthalmic Surg Lasers 1997; 28: 957–960.
Collins DW, Coroneo MT . Removal of corneal foreign bodies: an instructional model. Ophthalmic Surg 1994; 25: 99–101.
Coroneo MT . The bovine eye as a model for the novice cataract surgeon. Ophthalmic Surg 1990; 21: 772–777.
Atsushi M, Junko N, Jiro N, Hirohumi H, Takashi K, Kazutaka K . Cataract surgery training using pig eyes filled with chestnuts of various hardness. J Cataract Refract Surg 1999; 25: 622–625.
Hashimoto C, Kurosaka D, Uetsuki Y . Teaching continuous curvilinear capsulorhexis using a postmortem pig eye with simulated cataract. J Cataract Refract Surg 2001; 27: 814–816.
Sugiura T, Kurosaka D, Uezuki Y . Creating cataract in a pig eye. J Cataract Refract Surg 1999; 25: 615–621.
Dada VK, Sindhu N . Cataract in enucleated goat eyes: training model for phacoemulsification. J Cataract Refract Surg 2000; 26: 1114–1116.
Sudan R, Titiyal JS, Rai H, Chandra P . Formalin-induced cataract in goat eyes as a surgical training model for phacoemulsification. J Cataract Refract Surg 2002; 28: 1904–1906.
Sudan R, Titiyal JS, Sethi HS, Rai HK . Animal model for teaching phacoemulsification. J Cataract Refract Surg 2002; 28: 4–5.
Tolentino FI, Liu HS . A laboratory animal model for phacoemulsification practice. Am J Ophthalmol 1975; 80: 545–546.
Yip CC, Heng WJ, Au-Eong KG, Yong VS . A novel approach for the fixation of enucleated eyes during microsurgical procedures using common household plumbing accessories. Ophthalmic Surg Lasers 2001; 32: 166–167.
Author information
Authors and Affiliations
Corresponding author
Additional information
The authors have no financial or propriety interest in any material or method mentioned
Presented in part at the European Glaucoma Society Meeting in Florence, Italy, 2004
Rights and permissions
About this article
Cite this article
Lee, G., Chiang, MM. & Shah, P. Pig eye trabeculectomy—a wet-lab teaching model. Eye 20, 32–37 (2006). https://doi.org/10.1038/sj.eye.6701784
Received:
Accepted:
Published:
Issue date:
DOI: https://doi.org/10.1038/sj.eye.6701784
Keywords
This article is cited by
-
A systematic review of simulation-based training tools for technical and non-technical skills in ophthalmology
Eye (2020)
-
A novel wet-lab teaching model for trabeculectomy surgery
Eye (2018)
-
Trabeculectomy training in England: are we safe at training? Two year surgical outcomes
Eye (2018)
-
Rapid learning curve assessment in an ex vivo training system for microincisional glaucoma surgery
Scientific Reports (2017)
-
Indentation and needle insertion properties of the human eye
Eye (2014)