Table 2 Summer environmental control program
Period | Daytime (06:00 ~ 22:00) | Nighttime (22:00 ~ 06:00) |
|---|---|---|
Case1 (July 6–13) | D3 closed; air conditioner and dehumidifier off | D3 open; air conditioner on (16 °C), dehumidifier on (55% RH) |
Case2 (July 13–20) | D3 closed; air conditioner on (16 °C), dehumidifier on (55% RH) | D3 open; air conditioner on (16 °C), dehumidifier on (55% RH) |
Case3 (July 20–27) | D3 closed; air conditioner on (16 °C), dehumidifier on (55% RH) | D3 closed; air conditioner off, dehumidifier off. |