Table 1 Summary of microfluidic systems for particle and bioparticle separation

From: Dean migration mechanisms: facilitating the control of microbial contaminants in cell therapy product manufacturing

Bioparticles of interest

H (μm)

W (μm)

Flow rate ratio µl/min

Re

Beads (μm)

ap/h

Separation efficiency(%)

Type of manipulation

Evs (20–200 nm)23

55

300

420 (1:20)

42

0.05–2

0.036

60

(i)

Mps (0.1–1 μm)22

55

300

660 1:10)

30-50

0.05-3

0.054

80

(i)

Beads (1.9 μm)34

50

100

20 (Null)

5

1.9&7.32

0.038

Null

(ii)

E.coli (<3 μm)20

80

500

1700 (3:31)

97.7

Null

0.038

>65

(ii)

E.coli (<3 μm)21

20

50

78 (1:5)

37.14

0.81,2.29,4.7

0.045

98

(ii)

Platelets (2–3 μm)35

115

500

1430 (1:10)

77.5

Null

0.026

>80

(ii)

Nps (<5 μm)36

115

500

1320 (1:10)

71.5

2–5

0.043

>95

(ii)

S.aureus &E.coli (<3 μm)37

70

200

500 (1:4)

79.4

1.84,6.04,10.6

0.043

70.6-82.5

(ii)

  1. (i) Low Reynolds number condition. (ii) Moderate Reynolds number condition
  2. Evs extracellular vesicles, Nps Nanoparticles, MVs Microvesicles, Null No data available