Table 1 Three plane localizer

From: Impact of preoperative prostate magnetic resonance imaging on the surgical management of high-risk prostate cancer

Ā 

Three plane localizer

Small FOV T2 (3-plane)

Small FOV

Axial T1

Small FOV

Axial DWI

Whole pelvis

Axial T1 pre-contrast

Whole pelvis

Axial DWI

Small FOV

Axial 3D DCE

Pulse sequence

Gradient echo

FSE-XL/NPW, EDR, TRF

FSE-XL/NPW, EDR, TRF

Spin echo/EDR, EPI

FSE-XL/NPW, EDR, TRF

Spin echo/EDR, EPI

SPGR/ EDR, fast, multi-phase

TR (ms)

4.768

4000

660

8000

660

11,000

3.7

TE (ms)

1.252

140

9

78

9

64

1.7

Flip angle (°)

30

90

90

–

90

–

25

BW (kHz)

25

19.23

245

20

240

42

Ā 

FOV (cm)

40

14

14

14

24

38

26

Slice thickness (mm)

5

3

3

3

6

5

3

Spacing (mm)

2

0

0

0

0

0

0

Frequency direction

Unswap

Ax/Sg–A/P

A/P

R/L

R/L

R/L

R/L

Co–S/I

Matrix

256 × 128

256 × 224

256 × 224

128 × 96

256 × 192

160 × 96

160 × 128

NEX

2

4

4

2

2

2

1

Echo train length

1

18

3

1

3

1

1

  1. FSE fast spin echo, SPGR spoiled gradient echo, EPI echo-planar imaging, NPW no phase wrap, TRF tailored radio frequency, EDR extended dynamic range, TR repetition time, TE echo time, BW bandwidths, FOV field of view, ETL echo train length, NEX number of excitations, Co coronal, Ax/Sg axial/sagittal, A/P anterior/posterior, R/L right/left, S/I superior/inferior