Abstract
Objectives
To evaluate the safety, efficacy, and feasibility of an endoscopic transconjunctival inferior fornix and precaruncular approach for repair of combined orbital medial wall and floor fractures involving the inferomedial strut.
Methods
A retrospective study was performed in 84 patients with combined orbital medial wall and floor fractures involving the inferomedial strut. All patients underwent surgery by endoscopic transconjunctival inferior fornix and precaruncular approach. A large polyester mesh plate was implanted to cover the fracture defect. The enophthalmos, diplopia, and surgical complications were evaluated pre- and postoperatively. Patients were followed for at least 6 months.
Results
A total of 84 patients (55 men and 29 women) with a mean age of 36.88 ± 12.95 years were included in this study. Preoperatively, all 84 patients had an enophthalmos >2 mm, and the mean exophthalmometry measurement was 11.6 ± 2.14 mm. Diplopia was presented in 33 patients. Postoperatively, good symmetry was acquired in 81 of 84 patients, with a mean improvement of 3.02 ± 0.99 mm in the enophthalmos (P < 0.05). Recovery from diplopia occurred in 32 of 33 patients. A new onset of diplopia occurred postoperatively in 13 of the remaining 51 patients, only to recover spontaneously after 1 month. One patient suffered retrobulbar hemorrhage after surgery and was cured by conservative therapy. No other serious complications occurred.
Conclusions
The endoscopic transconjunctival inferior fornix and precaruncular approach is a promising management technique for combined orbital medial wall and floor fractures involving the inferomedial strut.
Similar content being viewed by others
Log in or create a free account to read this content
Gain free access to this article, as well as selected content from this journal and more on nature.com
or
References
Nagasao T, Miyamoto J, Jiang H, Tamaki T, Kaneko T. Interaction of hydraulic and buckling mechanisms in blowout fractures. Ann Plast Surg. 2010;64:471–6.
Su GW, Harris GJ. Combined inferior and medial surgical approaches and overlapping thin implants for orbital floor and medial wall fractures. Ophthalmic Plast Reconstr Surg. 2006;22:420–3.
Cole P, Boyd V, Banerji S, Hollier LH Jr. Comprehensive management of orbital fractures. Plast Reconstr Surg. 2007;120 7 Suppl 2:57S–63S.
Chen CT, Pan CH, Chen CH, Shyu VB, Wu JC, Kang GC. Clinical outcomes for minimally invasive primary and secondary orbital reconstruction using an advanced synergistic combination of navigation and endoscopy. J Plast Reconstr Aesthet Surg. 2018;71:90–100.
Wu W, Jing W, Selva D, Cannon PS, Tu Y, Chen B. Endoscopic transcaruncular repair of large medial orbital wall fractures near the orbital apex. Ophthalmology. 2013;120:404–9.
Kim K, Song K, Choi S, Bae Y, Choi C, Oh H, et al. Endoscopic transnasal approach for the treatment of isolated medial orbital blow-out fractures: a prospective study of preoperative and postoperative orbital volume change. Ann Plast Surg. 2012;68:161–5.
Wu W, Yan W, Cannon PS, Jiang AC. Endoscopic transethmoidal and transconjunctival inferior fornix approaches for repairing the combined medial wall and orbital floor blowout fractures. J Craniofac Surg. 2011;22:537–42.
Chang M, Yang SW, Park JH, Lee J, Lee H, Park MS, et al. Using the endoscopic transconjunctival and transcaruncular approach to repair combined orbital floor and medial wall blowout fractures. J Craniofac Surg. 2017;28:963–6.
Cho RI, Davies BW. Combined orbital floor and medial wall fractures involving the inferomedial strut: repair technique and case series using preshaped porous polyethylene/titanium implants. Craniomaxillofac Trauma Reconstr. 2013;6:161–70.
Hur SW, Kim SE, Chung KJ, Lee JH, Kim TG, Kim YH. Combined orbital fractures: surgical strategy of sequential repair. Arch Plast Surg. 2015;42:424–30.
Nam SB, Bae YC, Moon JS, Kang YS. Analysis of the postoperative outcome in 405 cases of orbital fracture using 2 synthetic orbital implants. Ann Plast Surg. 2006;56:263–7.
Bevans SE, Moe KS. Advances in the reconstruction of orbital fractures. Facial Plast Surg Clin North Am. 2017;25:513–35.
Westfall CT, Shore JW, Nunery WR, Hawes MJ, Yaremchuk MJ. Operative complications of the transconjunctival inferior fornix approach. Ophthalmology. 1991;98:1525–8.
Moe KS. The precaruncular approach to the medial orbit. Arch Facial Plast Surg. 2003;5:483–7.
You HJ, Kim DW, Dhong ES, Yoon ES. Precaruncular approach for the reconstruction of medial orbital wall fractures. Ann Plast Surg. 2014;72:652–6.
Harris GJ. Orbital blow-out fractures: surgical timing and technique. Eye. 2006;20:1207–12.
Nowinski D, Messo E, Hedlund A. Treatment of orbital fractures: evaluation of surgical techniques and materials for reconstruction. J Craniofac Surg. 2010;21:1033–7.
Edgin WA, Morgan-Marshall A, Fitzsimmons TD. Transcaruncular approach to medial orbital wall fractures. J Oral Maxillofac Surg. 2007;65:2345–9.
Lee CS, Yoon JS, Lee SY. Combined transconjunctival and transcaruncular approach for repair of large medial orbital wall fractures. Arch Ophthalmol. 2009;127:291–6.
Oh TS, Jeong WS, Chang TJ, Koh KS, Choi JW. Customized orbital wall reconstruction using three-dimensionally printed rapid prototype model in patients with orbital wall fracture. J Craniofac Surg. 2016;27:2020–4.
Park SW, Choi JW, Koh KS, Oh TS. Mirror-imaged rapid prototype skull model and pre-molded synthetic scaffold to achieve optimal orbital cavity reconstruction. J Oral Maxillofac Surg. 2015;73:1540–53.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
The authors declare that they have no conflict of interest.
Additional information
Publisher’s note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
About this article
Cite this article
Zhou, G., Tu, Y., Yu, B. et al. Endoscopic repair of combined orbital floor and medial wall fractures involving the inferomedial strut. Eye 35, 2763–2770 (2021). https://doi.org/10.1038/s41433-020-01304-0
Received:
Revised:
Accepted:
Published:
Version of record: