Abstract
Objective
To assess visible aerosol generation during simulated vitrectomy surgery.
Methods
A model comprising a human cadaveric corneoscleral rim mounted on an artificial anterior chamber was used. Three-port 25 gauge vitrectomy simulated surgery was performed with any visible aerosol production recorded using high-speed 4K camera. The following were assessed: (1) vitrector at maximum cut rate in static and dynamic conditions inside the model, (2) vitrector at air–fluid interface in a physical model, (3) passive fluid–air exchange with a backflush hand piece, (4) valved cannulas under air, and (5) a defective valved cannula under air.
Results
No visible aerosol or droplets were identified when the vitrector was used within the model. In the physical model, no visible aerosol or droplets were seen when the vitrector was engaged at the air–fluid interface. Droplets were produced from the opening of backflush hand piece during passive fluid–air exchange. No visible aerosol was produced from the intact valved cannulas under air pressure, but droplets were seen at the beginning of fluid–air exchange when the valved cannula was defective.
Conclusions
We found no evidence of visible aerosol generation during simulated vitrectomy surgery with competent valved cannulas. In the physical model, no visible aerosol was generated by the high-speed vitrector despite cutting at the air–fluid interface.
Similar content being viewed by others
Log in or create a free account to read this content
Gain free access to this article, as well as selected content from this journal and more on nature.com
or
References
Chandra A, Haynes R, Burdon M, Laidlaw A, Neffendorf J, Eames I, et al. Personal protective equipment (PPE) for vitreoretinal surgery during COVID-19. Eye. 2020;12:1–4.
Royal College of Ophthalmologists. Vitreoretinal surgery during COVID-19 pandemic. http://www.rcophth.ac.uk/wp-content/uploads/2020/04/. Accessed 30 May 2020.
American Academy of Ophthalmology. Special considerations for ophthalmic surgery during the COVID-19 pandemic. http://www.aao.org/headline/special-considerations-ophthalmic-surgery-during-c. Accessed 30 May 2020.
Wong R, Banerjee P, Kumaran N. Aerosol generating procedures in intraocular surgery. Eye. 2020. https://doi.org/10.1038/s41433-020-0997-7.
Koshy ZR, Dickie D. Aerosol generation from high speed ophthalmic instrumentation and the risk of contamination from SARS COVID19. Eye. 2020. https://doi.org/10.1038/s41433-020-1000-3.
National Institute for Occupational Safety and Health. Generation and behavior of airborne particles (Aerosols). http://www.cdc.gov/niosh/topics/aerosols/pdfs/Aerosol_101.pdf. Accessed 30 May 2020.
Sigler EJ, Charles S, Calzada JI. Interface vitrectomy. Retina. 2014;34:616–7.
Li KKW, Joussen AM, Kwan JKC. Steel DHWFFP3, FFP2, N95, surgical masks and respirators: what should we be wearing for ophthalmic surgery in the COVID-19 pandemic? Graefes Arch Clin Exp Ophthalmol. 2020. https://doi.org/10.1007/s00417-020-04751-3.
Darcy K, Elhaddad O, Achiron A, Keller J, Leadbetter D, Tole D, et al. Reducing visible aerosol generation in the era of Covid-19. medRxiv. https://doi.org/10.1101/2020.05.14.20102301. Accessed 30 May 2020.
The Royal College of Ophthalmologists. Theatre facilities and equipment. http://www.rcophth.ac.uk/wp-content/uploads/2018/12/Theatre-facilities-equipment.pdf. Accessed 30 May 2020.
Tang JW, Li Y, Eames I, Chan PKS, Ridgway GL. Factors involved in the aerosol transmission of infection and control of ventilation in healthcare premises. J Hosp Infect. 2006;64:100–14.
Acknowledgements
The authors wish to acknowledge the support of NHS Blood and Transplant.
Funding
The authors received no financial support for the research, authorship, and/or publication of this article.
Author information
Authors and Affiliations
Corresponding authors
Ethics declarations
Conflict of interest
The authors declare that they have no conflict of interest.
Additional information
Publisher’s note Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
About this article
Cite this article
Liyanage, S., Ramasamy, P., Elhaddad, O. et al. Assessing visible aerosol generation during vitrectomy in the era of Covid-19. Eye 35, 1187–1190 (2021). https://doi.org/10.1038/s41433-020-1052-4
Received:
Revised:
Accepted:
Published:
Version of record:
Issue date:
DOI: https://doi.org/10.1038/s41433-020-1052-4
This article is cited by
-
Phacoemulsification and nucleic acid-enriched aerosol: considerations from an eye model of cataract simulation
Graefe's Archive for Clinical and Experimental Ophthalmology (2021)
-
Novel Insights into the Transmission of SARS-CoV-2 Through the Ocular Surface and its Detection in Tears and Conjunctival Secretions: A Review
Advances in Therapy (2020)