Table 1 Summary of measured parameters for on-chip graph states

From: Programmable four-photon graph states on a silicon chip

State

Fidelity

\({\mathscr{M}}_{\boldsymbol{II}}^{\boldsymbol{G}}\) (2,4)

\({\mathscr{{M}}}_{\boldsymbol{III}}^{\boldsymbol{G}}\)

Count rate

Counts

|S4

0.78 ± 0.01

3.17 ± 0.07

12.45 ± 0.13 (12, 16)

5.7 mHz

2640

|L4

0.68 ± 0.02

2.61 ± 0.13

10.93 ± 0.29 (12, 16)

1.1 mHz

1085

|S41,3,4

0.77 ± 0.01

2.79 ± 0.09

6.16 ± 0.11 (6, 8)

3.3 mHz

1142

|S41,4

0.83 ± 0.02

3.32 ± 0.09 (2, 4)

4.0 mHz

416

|S43,4

0.83 ± 0.02

3.31 ± 0.09 (2, 4)

4.1 mHz

369

+1,3

0.97 ± 0.01

2.79 ± 0.01a

3.90 ± 0.03 (2, 4)

1.8 kHz

38003

+2,4

0.97 ± 0.01

2.71 ± 0.01a

3.88 ± 0.03 (2, 4)

1.9 kHz

41769

  1. State fidelities, Mermin test parameters, and photon statistics are listed. Classical and quantum bounds are listed in parentheses, where they apply
  2. aIndicates a Bell-CHSH test. All error bars represent the standard error of the mean, obtained from Monte Carlo simulations assuming a Poissonian distribution of the measured counts