Table 1 PLQYs (ηPL) under carrier density of ~1.2 × 1015 and ~2.3 × 1017 cm−3, monomolecular (k1), bimolecular (k2), and trimolecular (k3) recombination constant, estimated defect state density (Nt) and hole mobility (μ) of different quasi-2D perovskite films.

From: Reducing the impact of Auger recombination in quasi-2D perovskite light-emitting diodes

 

ηPL

ηPL

k1 (s−1)

k2 (cm3 s−1)

k3 (cm6 s−1)

Nt (cm−3)§

μ (cm2 V−1 s−1)§

PEA

0.66

0.22

1.2(±0.1) × 107

8.7 (±1.0) × 10−10

7.9 (±2.1) × 10−27

2.6 × 1016

0.8 × 10−3

p-FPEA

0.51

0.48

7.4(±0.4) × 106

1.2 (±0.4) × 10−10

3.2 (±0.9) × 10−28

2.1 × 1016

2.2 × 10−3

CF3KO3S-PEA

0.85

0.30

1.1(±0.1) × 107

9.1 (±0.9) × 10−10

8.3 (±3.2) × 10−27

1.7 × 1015

1.2 × 10−3

CF3KO3S-p-FPEA

0.82

0.55

5.3(±0.2) × 106

1.4 (±0.3) × 10−10

3.6 (±0.8) × 10−28

1.3 × 1015

3.2 × 10−3

  1. Measured under the carrier density of ~1.2 × 1015 cm−3.
  2. Measured under the carrier density of ~2.3 × 1017 cm−3.
  3. §Extracted from SCLC measurements.