Table 1 Analytical instruments and analysis locations.

From: A new conceptual framework for the transformation of groundwater dissolved organic matter

Analysis type

Analytical instrument

Analysis location

Cations

Perkin Elmer NexION 300D inductively coupled plasma (ICP) mass spectrometer and Perkin Elmer Optima 7300 ICP optical emission spectrometer

Mark Wainwright Analytical Centre (UNSW Sydney)

Anions

Dionex Ion Chromatography System with an IonPac AS14A analytical column

Mark Wainwright Analytical Centre (UNSW Sydney)

N-NO3 and N-NH4

Lachat flow injection analyser

Mark Wainwright Analytical Centre (UNSW Sydney)

δ2H and δ18O

Off-Axis Integrated Cavity Output Spectroscopy using an LGR Liquid Water Isotope Analyser111

UNSW Sydney

δ13CDIC

Delta V Advantage Isotope Ratio Mass Spectrometer

Australian Nuclear Science and Technology Organisation (ANSTO)

δ13CDOC

O.I. Analytical Model 1030 Total Organic Carbon Analyzer interfaced to a PDZ Europa 20-20 isotope ratio mass spectrometer utilizing a GD-100 Gas Trap Interface.

UC Davis Stable Isotope Facility, California

14CDOC

Accelerator Mass Spectrometry

Australian Nuclear Science and Technology Organisation (ANSTO)

14CDIC

Accelerator Mass Spectrometry

Australian Nuclear Science and Technology Organisation (ANSTO)

Total DOC

Aurora 1030 wet oxidation TOC analyser

Mark Wainwright Analytical Centre (UNSW Sydney)

Fluorescence

Horiba Scientific Aqualog fluorometer

UNSW Sydney

LC-OCD

DOC-LABOR LC-OCD size-exclusion chromatography

Mark Wainwright Analytical Centre (UNSW Sydney)

FT-ICR MS

Negative mode (−) electrospray ionisation (ESI) on a 21 Tesla super conducting magnet (Bruker, U.S.)90,91

National High Magnetic Field Laboratory, Tallahassee, Florida