Table 1 Actuator sensitivities

From: Phase-stabilised self-injection-locked microcomb

Sensitivity

foff

frep

Ip

27 MHz/mA

160 kHz/mA

Ih

160 MHz/mA

400 kHz/mA

  1. Sensitivity of the SIL microcomb’s offset frequency foff and repetition rate frep to the DFB current Ip and micro-heater current Ih. The values were measured around the experiment set point of  ~180 mA and 3 mA, respectively. A theoretical derivation of the actuator tuning coefficients is presented in Section 1 and 2 of the Supplementary Information.