Table 1 Critical temperatures of TX2
Materials | Experiment | Prediction |
|---|---|---|
Bulk 1T-TiSe2 | 202 K54 | 173 ± 11 K |
Bulk 1T-TaS2 | 225 K55 | 280 ± 36 K |
Monolayer 1T-TiSe2 | 232 ± 5 K33 230 K34 245 K35 | 240 ± 15 K |
Monolayer 2H-NbSe2 | 145 ± 3 K56 | 124 ± 5 K |
Monolayer 2H-TaS2 | 93 K57 55 ± 7 K58 | 95 ± 4 K |
Bulk 2H-TaSe2 | 120.6 K59 122.3 K60 | 119 ± 14 K |
Bulk 2H-TaS2 | 77 K59 80 K61 | 96 ± 3 K |
Bulk 2H-NbSe2 | 33 K62 33.5 K60 | 75 K |