Table 5 Description of the variables contained in the *Data.mat file for the tensile dog bones.

From: Digital image correlation and infrared thermography data for seven unique geometries of 304L stainless steel

Variable

Description

Units

Size

time

Elapsed time (time=0 marks the start of applied force)

s

[NumTime,1]

strain

Engineering strain along the longitudinal direction (Y axis) calculated from the virtual extensometer according to Eqn. (2)

mm/mm

[NumTime,1]

force

Force measured by the standard load cell along the Y axis

kN

[NumTime,1]

IR_temperature_P*

Temperature measured by the IR camera at the two ends (P1 and P2) and the center (P0) of the virtual extensometer; two temperatures are provided, calculated with the bounds on the emissivity specified in Table 3

oC

[NumTime,2]

  1. In the “Size” column, NumTime is the number of time steps.