Table 5 Detailed imaging parameters of the Multiparametric Liver MRI2 protocol.
From: A preclinical CT and MRI Liver Imaging Dataset with Anatomical, Functional and Segmentation Data
Data type | Details (type of sequence) |
|---|---|
T2 relaxometry (pre and post ferucarbotran (MSME)) | - FOV, 40 × 40 mm2 - matrix, 144 × 144 - echo times (7, 13, 20, 27, 34, 40, 47, 54, 60, 67, 74, 81, 87, 94, 101, 107, 114, 121, 128, 134, 141, 148, 154, 161, 168 ms) - repetition time, 2000 ms - echo spacing, 6.7 ms - resolution, 278 μm/pixel - in-plane - (axial) slice thickness, 1 mm with 0.25 mm slice gaps - bandwidth, 76 kHz |
dynamic susceptibility contrast MRI (EPI) | - FOV, 40 × 40 mm2 - matrix, 96 × 96 - effective echo time, 13 ms - repetition time, 1000 ms - echo spacing, 6.7 ms - resolution, 417 μm/pixel - in-plane - (axial) slice thickness, 1 mm without slice gaps - bandwidth, 250 kHz |
repetition of anatomical T2-weighted spin echo (post ferucarbotran (RARE)) | - see above |