Table 8 ANN results under the different noisy events.

From: Enhancing HVDC transmission line fault detection using disjoint bagging and bayesian optimization with artificial neural networks and scientometric insights

Noise (db)

Fault locations

Fault resistance (Ω)

Type of faults

Threshold

DC line protection

1st

2nd

3rd

Faulty

Healthy

25

10 km of DC link

10

PTP

PTG

NPT

X

X

1

0

60

PTP

PTG

NPT

X

X

1

0

135

PTP

PTG

NPT

X

X

1

0

20

30 km of DC link

260

PTP

PTG

NPT

X

X

1

0

285

PTP

PTG

NPT

X

X

1

0

335

PTP

PTG

NPT

X

X

1

0

30

180 km of DC link

10

PTP

PTG

NPT

X

X

1

0

110

PTP

PTG

NPT

X

X

1

0

335

PTP

PTG

NPT

X

X

1

0

Normal operation

X

X

X

X

X

X

X

X

0

1