Table 5 Simulation output readings for the motor using VSD.
From: Energy saving analysis for pump-motor set in water purification plant using variable speed drive
Time (s) | % Loading | Vrms (V) | \(\:{\text{I}}_{\text{rms}}\) (A) | F (Hz) | P.F | ⍵ (rad/s) | Td (Nm) | Pin (kω) | Energy (kω h) |
|---|---|---|---|---|---|---|---|---|---|
3–6 | 100 | 401.9 | 230.9 | 49.92 | 0.848 | 156 | 852 | 132 | 0 |
6–9 | 90 | 361.7 | 196.6 | 44.9 | 0.828 | 140.4 | 699 | 101.9 | 76.5 |
9–12 | 80 | 323.9 | 168 | 39.89 | 0.783 | 124.8 | 554 | 73.7 | 959.4 |
12–15 | 70 | 285 | 145.4 | 34.89 | 0.739 | 109.2 | 426.3 | 53.4 | 547.35 |
1582.25 |