Table 5 Simulation output readings for the motor using VSD.

From: Energy saving analysis for pump-motor set in water purification plant using variable speed drive

Time (s)

% Loading

Vrms (V)

\(\:{\text{I}}_{\text{rms}}\) (A)

F (Hz)

P.F

⍵ (rad/s)

Td (Nm)

Pin (kω)

Energy (kω h)

3–6

100

401.9

230.9

49.92

0.848

156

852

132

0

6–9

90

361.7

196.6

44.9

0.828

140.4

699

101.9

76.5

9–12

80

323.9

168

39.89

0.783

124.8

554

73.7

959.4

12–15

70

285

145.4

34.89

0.739

109.2

426.3

53.4

547.35

         

1582.25