Table 12 Statistical results obtained using 3000 iterations in 7-parameter RTC – France cell.

From: Application of improved Jellyfish search algorithm for 9-parameters cell extraction and GMPPT in PV systems

Algorithm

Simulation time

RMSE

Worst RMSE

Average RMSE

Standard deviation

FSSO

758.373

1.1573E-03

6.3070E-01

6.3372E-02

9.7598E-02

HHO

545.645

1.3364E-03

6.3388E-01

1.2866E-01

1.3911E-01

MFO

653.41

1.0025E-03

9.2327E-03

2.3528E-03

1.4223E-03

IJSO

243.534

9.8413E-04

9.8600E-04

9.8417E-04

2.3800E-07