Table 3 Shows the values of the parameters sensitivity (S), quality factor (Q), figure of merit (FOM), signal-to- noise ratio (SNR), detection limit (δn), and sensor resolution (SR) at different thickness of GaN dA from100 to 900 nm, the air thickness dB = 200 nm, the incident angle θ = 30º, number of GaN/air periods N = 3 and the defect thickness Ddef = 900 nm with identification the temperature range, wavelength range and shift direction for each thickness.

From: Maximizing temperature sensitivity in a one-dimensional photonic crystal thermal sensor

dA

S (nm/ºC)

QF

FOM (ºC−1)

SNR

δn (ºC)

SR (nm)

Temp. range

Wavelength range (nm)

Shift direction

100

10.088

35,443.258

621.462

12,030.150

5.691

0.674

20–50

400–700

blue

200

8.158

96,101.415

1590.882

6675.526

7.275

59.357

20–45

410–610

blue

300

6.798

18,100.882

177.159

2528.812

13.242

90.022

20–40

610–725

blue

400

5.901

45,793.603

447.025

29,468.163

11.875

70.080

20–40

540–657

blue

500

5.008

72,411.983

656.275

2535.399

14.951

74.889

20–40

508–605

blue

600

4.747

42,374.683

306.792

2212.286

17.0004

80.708

20–35

610–682

blue

700

3.854

53,812.996

343.475

134,814.539

20.958

80.786

20–40

560–640

blue

800

3.455

76,593.859

465.465

1240.809

24.954

86.220

20–40

535–605

blue

900

3.591

59,342.563

334.081

1386.438

22.617

81.223

20–35

605–660

blue