Table 2 Specifications of the hybrid DC microgrid with CPL.

From: A passivity based nonlinear controller for hybrid DC microgrid with constant power loads

Parameters

Nominal values

Inductance, L1 and L2

5.5mH and 3.5mH

Capacitance, C1 and C2

\(5 \times 10^{-6}\)F and \(8 \times 10^{-6}\)F

Source Voltages, E1 and E2 and CPL

360 V and 120 V, 5 KW

DC Bus Voltage, \(V_o\)

500V

Switching Frequency, fs

20kHz

PV module

Maximum power

215W

Voltage across open circuit

36.12V

Current through short circuit

7.72A

Series Module number

13

Parallel strings number

2

Wind turbine

Nominal power

\(1 \times 10^{3}\)W

Cut-off speed

12m/s