Table 2 Equivalent von mises stress (MPa) around natural tooth (Mandibular 1st Molar).

From: Comparative analysis of occlusal stresses on bone around natural teeth, platform matched and switched implants abutments: a finite element study

Model

Part

Minimum

Maximum

Average

Model-1 (Natural Tooth Mandibular 1st Molar)

Overall

1.62E-07

1.81E + 01

2.98E-01

Cancellous

4.96E-03

5.57E +00

1.65E-01

Cortical

2.18E-03

1.81E +01

4.08E-01

Periodontal ligament

4.22E-04

7.45E-01

1.99E-01

Tooth

2.44E-02

1.47E +01

1.12E +00