Table 6 Analysis of the degree of influence of factors.
From: Research on the electro-magnetic-thermal–mechanical characteristics of shearer cables
Magnetic flux density mode(mT) | Current density mode(A/mm2) | Volume loss density(MW/m3) | |||||||
|---|---|---|---|---|---|---|---|---|---|
A | B | C | A | B | C | A | B | C | |
K1 | 24.350 | 33.140 | 19.900 | 27.570 | 42.000 | 22.800 | 4.389 | 10.440 | 3.234 |
K2 | 24.320 | 22.740 | 22.610 | 30.860 | 29.560 | 28.420 | 6.324 | 5.180 | 5.270 |
K3 | 24.230 | 17.020 | 30.390 | 30.440 | 17.310 | 37.650 | 6.690 | 1.783 | 8.899 |
k1 | 8.117 | 11.047 | 6.633 | 9.190 | 14.000 | 7.600 | 1.463 | 3.480 | 1.078 |
k2 | 8.107 | 7.580 | 7.537 | 10.287 | 9.853 | 9.473 | 2.108 | 1.727 | 1.757 |
k3 | 8.077 | 5.673 | 10.130 | 10.147 | 5.770 | 12.550 | 2.230 | 0.594 | 2.966 |
R | 0.040 | 5.373 | 3.497 | 1.097 | 8.230 | 4.950 | 0.767 | 2.886 | 1.888 |
S | 0.0003 | 4.949 | 2.197 | 0.238 | 11.289 | 4.164 | 0.113 | 1.410 | 0.610 |