Table 8 Comparison of experimental and simulated values.
From: Research on the electro-magnetic-thermal–mechanical characteristics of shearer cables
Sample number | Simulated outer surface temperature/℃ | Experimental outer surface temperature/℃ | Error /% | Simulated outer surface Equivalent stress/MPa | Experimental outer surface Equivalent stress/MPa | Error /% |
|---|---|---|---|---|---|---|
1 | 43.00 | 41.97 | 2.40 | 30.80 | 29.78 | 3.21 |
2 | 36.66 | 36.09 | 1.56 | 30.75 | 30.77 | 0.09 |
3 | 40.48 | 41.00 | 1.29 | 29.42 | 30.79 | 4.66 |
4 | 38.18 | 38.35 | 0.45 | 29.53 | 30.75 | 4.11 |
5 | 34.95 | 35.78 | 2.36 | 29.65 | 30.94 | 4.37 |
6 | 39.53 | 39.89 | 0.89 | 30.05 | 29.86 | 0.62 |
7 | 37.40 | 37.90 | 1.34 | 30.11 | 29.23 | 2.92 |
8 | 37.58 | 37.19 | 1.04 | 29.26 | 30.27 | 3.44 |
9 | 39.03 | 38.99 | 0.09 | 30.46 | 30.32 | 0.45 |
10 | 40.91 | 41.26 | 0.86 | 29.64 | 29.74 | 0.34 |