Table 8 Comparison of experimental and simulated values.

From: Research on the electro-magnetic-thermal–mechanical characteristics of shearer cables

Sample number

Simulated outer surface temperature/℃

Experimental outer surface temperature/℃

Error /%

Simulated outer surface Equivalent stress/MPa

Experimental outer surface

Equivalent stress/MPa

Error /%

1

43.00

41.97

2.40

30.80

29.78

3.21

2

36.66

36.09

1.56

30.75

30.77

0.09

3

40.48

41.00

1.29

29.42

30.79

4.66

4

38.18

38.35

0.45

29.53

30.75

4.11

5

34.95

35.78

2.36

29.65

30.94

4.37

6

39.53

39.89

0.89

30.05

29.86

0.62

7

37.40

37.90

1.34

30.11

29.23

2.92

8

37.58

37.19

1.04

29.26

30.27

3.44

9

39.03

38.99

0.09

30.46

30.32

0.45

10

40.91

41.26

0.86

29.64

29.74

0.34