Table 3 Correlation coefficients matrix of biometric parameters in the two groups.

From: A 10-year retrospective study on the prevalence and biometric characteristics of high myopia in Chinese cataract surgery candidates

Parameter

AL (mm)

K1 (D)

K2 (D)

K (D)

CD (mm)

ACD (mm)

CA (D)

AL/CR

ACD/AL

High myopia group

 K1a

0.042*

 K2a

0.069**

0.883***

 Ka

0.056**

0.968***

0.973***

 CDa

−0.046*

−0.449***

−0.477***

−0.478***

 ACDa

−0.080***

0.008

−0.013

−0.003

0.258***

 CAb

0.082***

−0.055*

0.370***

0.170***

−0.135***

−0.035

 AL/ CRb

0.909***

0.407***

0.432***

0.431***

−0.227***

−0.073**

0.143***

 ACD/ALa

−0.603***

−0.011

−0.039

−0.026

0.215***

0.821***

−0.071**

−0.554***

Non-high myopia group

 K1a

−0.548***

 K2a

−0.528***

0.889***

 Ka

−0.553***

0.971***

0.972***

 CDa

0.363***

−0.369***

−0.416***

−0.404***

 ACDa

0.379***

0.039***

0.001

0.020*

0.258***

 CAb

0.019*

−0.172***

0.229***

0.032***

−0.112***

−0.089***

 AL/ CRa

0.428***

0.319***

0.509***

0.515***

−0.065***

0.411***

0.040***

 ACD/ ALa

0.160***

0.170***

0.127***

0.153***

0.184***

0.959***

−0.070***

0.329***

  1. AL axial length, K keratometry, K1 flat keratometry, K2 steep keratometry, CD corneal diameter, ACD anterior chamber depth, CA corneal astigmatism, CR corneal radius of curvature.