Table 1 Comparison of baseline clinical data and aneurysm characteristics between the dual stents group and the single stent group.

From: LEO or LEO baby within enterprise overlapping stents combined with coil embolization treatment for ruptured vertebrobasilar artery dissecting aneurysms

Factor

Dual stents

group

N = 20

Single stent

group

N = 26

p-value

Age, years mean ± SD

58.25 ± 6.65

57.46 ± 7.56

0.71

Male sex, n (%)

11(55.00%)

12(46.15%)

0.77

Risk factors, n (%)

   

 Hypertension

13(65.00%)

20(76.92%)

0.51

 Diabetes mellitus

10(50.00%)

17(65.38%)

0.37

 Hyperlipidemia

11(55.00%)

19(73.08%)

0.23

Hunt-Hess grade, n (%)

  

0.76

 Grade 1–2

14(70.00%)

16(61.54%)

 

 Grade 3–5

6(30.00%)

10(38.46%)

 

Modified fisher, n (%)

  

0.54

 Grade 1–2

14(70.00%)

15(57.69%)

 

 Grade 3–4

6(30.00%)

11(42.31%)

 

Modified rankin scale, n (%)

  

0.76

 mRS 0–2

13(65.00%)

15(57.69%)

 

 mRS 3–6

7(35.00%)

11(42.31%)

 

NIHSS score, n (%)

  

0.76

 ≤ 5

13(65.00%)

15(57.69%)

 

 >5

7(35.00%

11(42.31%)

 

Size (mm)

8.02 ± 1.21

7.67 ± 1.02

0.42

Aneurysm location, n (%)

  

0.75

 BA

5(25.00%)

8(30.77%)

 

 VA

15(75.00%)

18(69.23%)

 
  1. Abbreviations: SD, standard deviation; NIHSS, The National Institutes of Health Stroke Scale.