Table 6 Location results of L1 under noise interference.
From: Fault location method for hybrid MTDC system based on LCC signal injection strategy
Fault location | Fault type | Fault measurement distance (km) | Error distance (km) |
|---|---|---|---|
f1 − 15 | PTG | 15.05 | 0.05 |
PTP | 15.07 | 0.07 | |
f1 − 250 | PTG | 251.47 | 1.47 |
PTP | 251.83 | 1.83 | |
f1 − 475 | PTG | 478.63 | 3.63 |
PTP | 472.46 | -2.54 | |
f1 − 700 | PTG | 705 | 5.00 |
PTP | 706.15 | 6.15 | |
f1 − 935 | PTG | 928.08 | -6.92 |
PTP | 943.61 | 8.61 |