Table B.1 Parameters of energy station.

From: Multi-time scaling optimization for electric station considering uncertainties of renewable energy and EVs

parameter

Value

Unit

Emission factor \({\lambda _{{\text{coal}}}}\)

0.68

kgCO₂/kW·h

Price of carbon \({c_{{\text{coal}}}}\)

0.1637

¥/kgCO₂

O & M coefficient of PV \({k_{{\text{PV}}}}\)

0.01

¥/kW

O & M coefficient of electrolyzer \({k_{{\text{EL}}}}\)

0.25

¥/kW

O & M coefficient of fuel cell \({k_{{\text{FC}}}}\)

0.15

¥/kW

O & M coefficient of hydrogen storage tank \({k_{{\text{HS}}}}\)

0.1

¥/Nm3