Table 1 Doubly-fed Induction Generator parameters.

From: A dual doubly-fed generator system supplied by a five-phase voltage inverter

Symbol

Quantity

Values

\(\textrm{R}_{\textrm{s}}\)

stator resistance

\(2.833 \Omega / 0.067 \textrm{p} . \textrm{u}\).

\(\textrm{R}_{\textrm{r}}\)

rotor resistance,

\(2.867 \Omega / 0.068 \textrm{p} . \textrm{u}\).

\(\textrm{L}_{\textrm{m}}\)

magnetizing inductance

\(0.15 \textrm{H} / 1.123 \textrm{p} . \textrm{u}\).

\(\textrm{L}_{\textrm{s},} \textrm{L}_{\textrm{r}}\)

stator and rotor inductance

\(0.164 \textrm{H} / 1.1227 \textrm{p} . \textrm{u}\)

\(\textrm{L}_{\sigma }\)

leakage inductance

\(0.014 \textrm{H} /\)

\(\textrm{P}_{\textrm{n}}\)

nominal power

2 kW

\(\textrm{I}_{\textrm{ns}}\)

nominal stator current

5.5 A

\(\textrm{I}_{\textrm{r}}\)

nominal rotor current

3.4 A

\(\textrm{U}_{\textrm{n}}\)

nominal stator voltage

400 V

\(\textrm{C}_{\textrm{f}}\)

load capacitance

30 uF

n

nominal rotor speed range

700-1300 rpm

f

nominal frequency

50 Hz

r

turn ratio \(\textrm{N}_{\textrm{s}} / \textrm{N}_{\textrm{r}}\)

1