Table 5 Comparison of performance metrics with pre- and post-layout results.

From: Design of low power energy efficient sigma-delta ADC for biomedical IoT applications

 

[2016]47

[2017]48

[2021]49

[2020]50

[2023]51

This Work (Pre / Post)

Technology (nm)

65

180

110

65

180

180

Supply (V)

0.3

1.5

1.5

1.1

1.8

1.8

Order

2

3

2

4

3

2

Sampling Frequency (MHz)

250 KHz

25.6

512 KHz

2560

25

1.28

Bandwidth (KHz)

1

100

2

20MHz

400

0.201

OSR

128

 

128

64

–

128

SNR (dB)

64.4

73.4

94

82.1

65

89.5 / 84.8

ENOB (bit)

10.4

12

–

–

12.6

14.57 / 13.995

FoM (fJ/conversion)

464

290

-

–

99

14.58 / 20.41

Area (\(mm^2\))

–

–

0.165

0.37

0.094

0.0896

Power (\(\mu\)W)

850

222.5

62.43

11300

100

454 / 498

  1. FoM (fJ/conversion): \(\text {FoM} = \frac{P}{2^{ENOB} \times f_s}\), ENOB Calculation: \(ENOB = \frac{SNDR - 1.76}{6.02}\)