Table 2 Detecting cognitive impairment using memory measures.

From: Equivalence of the FCSRT and RAVLT to detect medial Temporal lobe atrophy and tauopathy

 

FCSRT-IR

FCSRT-DR

RAVLT-IR

RAVLT-DR

AUC

0.810

[0.754, 0.867]

0.822

[0.766, 0.877]

0.815

[0.760, 0.870]

0.824

[0.770, 0.878]

Specificity

0.615

[1.000, 0.904]

0.558

[1.000, 0.913]

0.685

[1.000, 0.889]

0.537

[1.000, 0.898]

Sensitivity

0.938

[1.000, 1.000]

0.977

[1.000, 1.000]

0.852

[1.000, 0.989]

0.989

[1.000, 0.983]

  1. Receiver operating characteristic (ROC) analysis used Rey Auditory Verbal Learning Test (RAVLT) and Free and Cued Selective Reminding Test (FCSRT) delayed and immediate recalls (DR and IR) as predictors. AUC = area under the curve. AUC = area under the curve.