Table 3 Fourier analysis of back-EMF.
From: Analytical modeling of coreless stator axial flux permanent magnet machines under no-load condition
\(\:{\theta\:}_{sk}\:\left(Mech.\:deg.\right)\) | Fundamental component of EA | THD of EA |
|---|---|---|
\(\:{0}^{^\circ\:}\:\) | 6.4 (V) | 16.5% |
\(\:{10}^{^\circ\:}\) | 6.5 (V) | 15.91% |
\(\:{20}^{^\circ\:}\) | 6.448 (V) | 15% |
\(\:{30}^{^\circ\:}\) | 6.36 (V) | 13.68% |
\(\:{40}^{^\circ\:}\) | 6.23 (V) | 12% |
\(\:{50}^{^\circ\:}\) | 6.08 (V) | 10.11% |